| Specification |
Type: Smoke Alarm;
Usage: Smoke Detector;
Installation Mode: Built in;
Application: Industry, Communication Electronic Products, Special Equipment;
Rated Operational Voltage: DC12~24V;
Product Type: Smoke Detector with Relay Output;
Sound Pressure Level: Above 65dB;
Appliction: Security System,Industrial Control Equipment;
|
Type: Sensor;
Usage: Anti-theft;
Installation Mode: Handheld;
Application: Home, Industry, Communication Electronic Products, Special Equipment;
Product Name: Single Photocell Infrared Beam Sensor;
Warning Distance: Outdoor:15m, Indoor: 20m;
Beam: 1 Beam;
Light Source: Infrared LED;
Power Supply Voltage: DC12 ~ 24V;
Using Temperature: - 25 ° C~55 ° C;
Color: Black;
Function: Alarm;
Material: ABS Plastic;
Warranty: 1 Year;
|
Type: Sensor;
Usage: Anti-theft;
Installation Mode: Handheld;
Application: Home, Industry, Communication Electronic Products, Special Equipment;
Product Name: Single Photocell Infrared Beam Sensor;
Warning Distance: Outdoor:15m, Indoor: 20m;
Beam: 1 Beam;
Light Source: Infrared LED;
Power Supply Voltage: DC12 ~ 24V;
Using Temperature: - 25 ° C~55 ° C;
Color: Black;
Function: Alarm;
Material: ABS Plastic;
Warranty: 1 Year;
|
Type: Ultrovialet;
Usage: Flame;
Installation Mode: Ceiling Mounted;
Application: Home, Factory, Hotel, Apartment, Shopping Mall etc.;
Product Name: Ultrovialet Flame Detector;
Operating Voltage: 12-28VDC;
Standby Current: ≤10mA@24VDC;
Alarm Current: ≤30mA@24 VDC;
Wiring: 4 Wires;
Indicator: Two LEDs;
Working Status: LED Blinking in 5 Seconds Interval;
Spectrum: 180~290nm;
Detection Angle: 120 Degree;
Detection Sensitivity: Grade I, 25m@Flame;
Relay Contact Load: 1A@DC24V;
Delay Time Setting: 1s to 15s;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Dimention: About 103mm X 45mm;
|
Type: Ultrovialet;
Usage: Flame Detection;
Installation Mode: Wall Mounted;
Application: Home, Refinery, Gas Station, Chemical Plant etc.;
Product Name: Explosion Proof Ultrovialet Flame Detector;
Operating Voltage: 18-30VDC;
Standby Current: ≤25mA;
Alarm Current: ≤35mA;
LED Indicator: Green (Monitor),Red (Alarm),Yellow (Fault);
Wiring: 4 Wires;
Ingress Protection Leve: IP66;
Relay Contact Output: N.O and N.C;
Relay Contact Load: 3A@30VDC;
Detection Angle: 120 Degree;
Detection Distance: 15-35m;
Sensitivity Level: 1-5;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Materials: Aluminium Alloy, Surface Baking Finish;
|