| Specification |
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: ±2℃ Dew Point;
Customized: Customized;
Dp Range: -80 to +20℃ Dew Point;
Output: 4 to 20mA(Typical);
Supply: 9VDC (6VDC to 12VDC);
Operating Temp.: -30 to +50℃;
Repeatability: 0.5℃ Dew Point;
Operating Pressure: 15MPa;
Pressure Connection: G1/2’’ (Customization Available);
Housing Material: Stainless Steel;
Sensor Protection: Stainless Steel Weaving Filter with Pore Sizes < 8;
EMC: Comply with IEC 61326-1;
|
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.1;
IP Rating: IP20;
Customized: Customized;
Industrial Temperature Range: - 40 ~ + 85 Deg.C;
Installation: DIN35 Rail;
Two Output Signal: 4-20mA / 0-5V/0-10V Standard Signal;
One Input: Also Can Choose PT1000/Cu50/PT10/Cu100;
Auxiliary Power: DC5V, 9V, 12V, 15V, 24V;
Power: <2W;
Temperature Drift: 50ppm / ℃ (Typical);
Load Capacity: Voltage Output: ≥ 2 KΩ;
|
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.1;
IP Rating: IP20;
Customized: Customized;
Input: PT100 (-200~+600 ℃) (Range Selectable);
Output Signals: 4~20mA, 0~5V, 0-10V and Other Standard Signals;
Auxiliary Power Supply: 5V, 9V, 12V, 15V or 24V DC Single Power Supply;
Industrial Temperature Range: -40~+85 ℃;
Accuracy Level: 0.2 Level (Fsr%, Relative to Temperature);
Installation Method: DIN35 Rail Installation;
Response Time: ≤ 100ms;
|
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.1;
IP Rating: IP20;
Customized: Customized;
Typical Applications: Development of Medical and Industrial Control Prod;
Typical Applications1: PT100 Temperature Signal Measurement;
Typical Applications2: RS-485 Remote I/O, Data Acquisition;
Typical Applications3: RS485 Bus Industrial Automation Control System;
Typical Applications4: Equipment Operation Monitoring;
Input Type: PT100 Input/PT1000 Input;
Temperature Drift: ± 50 Ppm/ºC (± 100 Ppm/ºC,;
Bandwidth: -3 dB 10 Hz;
|
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.2;
IP Rating: IP20;
Customized: Non-Customized;
Installation Method: Supports Screw Installation and DIN35 Rail Install;
Input: Humidity and Temperature;
Communication Interface: WiFi Network Interface;
Typical Relative Humidity Accuracy: ±1.8%Rh;
Working Power Supply: Standard USB Type-C Interface with 5V Power Supply;
Operation Temperature: -40~+85℃;
Storage Temperature: -40~+85℃;
Product Features: Support Mqtt Timed Automatic Reporting of Temperat;
Contact Information: Please Contact Us Via Email or Online Customer Ser;
|