| Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting, Current, Power Energy, Monitoring;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Customized: Customized;
Display: Digital;
Stucture: Transformer;
Voltage: Low Voltage;
Brand: Grewin Clamp on Sensor;
Maximum Voltaget600VAC: Rated Primary Current 50A-3000A;
Maximum Non-Destructive Current: 3000A;
Current Probe Transformer Basic Accuracy: 1%;
Dielectric Resistance: 1000mohms @ 500 VDC;
Maximum Cable Diameter: 2.05 Inches (52 mm);
Approval: RoHS Compliant CE&ETL Approved;
Rated Output: 5A, 1A;
Core Material: Both Silicon Steel & Nickel Alloy Cores Available;
Current Sensor: Current Clamps with 0.333mv Output;
|
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Current Ratio: 10(100)a/4mA;
Magnetic Core: High Permeability Amorphous Nanoc;
Normal Ratio: 1000megohm;
Operating Temperature: -25℃~+75℃;
|
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Current Ratio: 10(100)a/4mA;
Magnetic Core: High Permeability Amorphous Nanoc;
Normal Ratio: 1000megohm;
Operating Temperature: -25℃~+75℃;
|
Application: Electronic;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
|
Application: Instrument, Metering;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv,7.2/30/60kv;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
Ambient Temperature: -5℃~+40℃;
|