| Specification |
Type: Infrared Gas Sensor;
Output Signal Type: Digital and Analog Signals;
Sensitivity: High;
Customized: Customized;
Operating Voltage Range: 3.0 - 5.0V D.C.;
Operating Current: 75 - 85mA / 15mA / 140mA;
Operating Temperature Range: -20°C to +50°C (-4°F to 122°F);
Warm up Time: 60s;
Humidity Range: 0 to 95% Rh Non-Condensing;
Standard Baud Rates: 38,400, 19,200, 9600, 4800;
Mtbf: > 5 Years;
Weight: 15g;
Measuring Range: 0-5%, 0-100% Volume or Both / 0 - 1%, 0-2%, 0-5% V;
Response Time T90: <30s;
|
Type: SemiConductor Gas Sensor;
Output Signal Type: Digital Type;
Material: Metal;
Sensitivity: High;
Customized: Non-Customized;
Product Name: Tvoc Sensor;
Detection Gas: Tvoc, CH2o, CO2;
Measure Range: Tvoc: 0-5000μG/M³ CO2: 400-5000ppm (Analo;
Resolution: 0.001 Mg/M³ or 1ppm;
Data Accuracy: Max. Error ≤10% Reading;
Service Life: 10 Years;
Stabilization Time: 3 Min;
Operating Voltage: DC 3.7~6.0V;
Output Modes: Default: Uart;
Default Output: Uart (3.3V_Ttl Level);
|
Type: SemiConductor Gas Sensor;
Conductivity Type: Volume Control Type;
Output Signal Type: Digital Type;
Material: Metal;
Sensitivity: High;
Customized: Non-Customized;
Product Name: Tvoc Sensor;
Detection Gas: Tvoc, CH2o, CO2, etc;
Tvoc Detection Range: 0-5000μG/M³;
Formaldehyde Detection Range: 0~1500μG/M³ (Analogue Output);
CO2 Dection Range: 400-5000ppm;
Resolution: 0.001 Mg/M³ , 1ppm;
Warm-up Time: 3 Min;
Operating Voltage: DC 3.3V;
Output Modes: Uart,Iic;
Service Life: 10 Years;
Data Accuracy: Max. Error ≤10% Reading;
Operating Temperature: 0ºC-50ºC;
|
Type: SemiConductor Gas Sensor;
Conductivity Type: Volume Control Type;
Output Signal Type: Digital Type;
Material: Metal;
Sensitivity: High;
Customized: Non-Customized;
Product Name: Tvoc Sensor;
Detection Gas: Tvoc, CH2o, CO2, etc;
Tvoc Detection Range: 0-5000μG/M³;
Formaldehyde Detection Range: 0~1500μG/M³ (Analogue Output);
CO2 Dection Range: 400-5000ppm;
Resolution: 0.001 Mg/M³ , 1ppm;
Warm-up Time: 3 Min;
Operating Voltage: DC 3.3V;
Output Modes: Uart,Iic;
Service Life: 10 Years;
Data Accuracy: Max. Error ≤10% Reading;
Operating Temperature: 0ºC-50ºC;
|
Type: Electrochemical Gas Sensor;
Conductivity Type: Surface Type;
Output Signal Type: Digital Type;
Material: Plastic;
Sensitivity: High;
Customized: Non-Customized;
Product Name: Alcohol Sensor;
Detection Gas: Alcoholic Gas;
Application: Breathalyzer Industrial Safety;
Measure Range: Default;0-500mg/100ml;
Resolution: 0.1mg/100ml or 0.1ppm;
Operating Voltage: DC 3.7 ~ 6V;
Operating Current: 10mA (@5V Power Supply);
Warm up Time: 2min;
Output Method: Uart;
Detection Frequency: Data Updates Once Per Second (Default);
Operating Temperature: 0~50ºC;
Operating Humidity: 15%~95%Rh (No Condensation);
|