| Specification |
After-sales Service: International Warranty;
Warranty: Two Years;
Appliance: Metals Analysis;
Ray Type: γ-Ray Spectrometer;
Gaspath System: X-ray;
Detector: Sdd Detector;
Energy Resolution: 135EV;
Spectrometer Detector: SDD;
Stationary Phase: Edxrf;
Mobile Phase: Edxrf;
Chromatography Type: Edxrf;
Chromatographic Column Type: None;
Chromatographic Column Length: None;
Chromatographic Column Diameter: None;
|
After-sales Service: Yes;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: No;
Gaspath System: No;
Detector: UV;
Energy Resolution: 2%;
Spectrometer Detector: UV;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: ID4.6*250mm;
Chromatographic Column Diameter: 2~5mm;
Weight: 30kg;
After Sales Service: Support;
Installtion Video: Yes;
Injection Mode: Manual(Autosampler as Option);
|
After-sales Service: Yes;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: No;
Gaspath System: No;
Detector: UV;
Energy Resolution: /;
Spectrometer Detector: UV;
Stationary Phase: /;
Mobile Phase: /;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: /;
Chromatographic Column Diameter: /;
Wavelength Range: 190nm-800nm, Single and Dual Wavelength Modes;
Wavelength Accuracy: 1nm;
Wavelength Precision: ± 0.1nm;
Linearity: 0-2au;
Baseline Noise: ± 0.5 X 10-5 Baseline Noise Au;
Power Supply: 100-240VAC, 50/6Hz, 75W;
|
After-sales Service: 24 Hours' on Line Service;
Warranty: on-Site Training;
Appliance: Dissolved in Oil;
Ray Type: Laser;
Gaspath System: Double;
Detector: PAS;
Energy Resolution: High Accuracy;
Spectrometer Detector: PAS;
Chromatography Type: Photoacoustic Spectroscopy;
Chromatographic Column Type: No Need;
Chromatographic Column Length: No Need;
Chromatographic Column Diameter: No Need;
Test Method: Photoacoustic Spectroscopy;
Light Source: Laser;
Tested Gas: Co, CO2, CH4, C2h2, C2h6, C2h4, H2O and etc.;
H2: 2 Ppm;
CO2: 25 Ppm;
Co: 25 Ppm;
CH4: 0.5 Ppm;
C2h2: 0.1 Ppm;
C2h4: 0.5 Ppm;
C2h6: 0.5 Ppm;
Moisture: 0~100 Ppm;
O2 & N2: Customized;
|
After-sales Service: 24 Hours' on Line Service;
Warranty: on-Site Training;
Appliance: Dissolved in Oil;
Ray Type: Laser;
Gaspath System: Double;
Detector: PAS;
Energy Resolution: High Accuracy;
Spectrometer Detector: PAS;
Chromatography Type: Photoacoustic Spectroscopy;
Chromatographic Column Type: No Need;
Chromatographic Column Length: No Need;
Chromatographic Column Diameter: No Need;
Test Method: Photoacoustic Spectroscopy;
Light Source: Laser;
Tested Gas: Co, CO2, CH4, C2h2, C2h6, C2h4, H2O and etc.;
H2: 2 Ppm;
CO2: 25 Ppm;
Co: 25 Ppm;
CH4: 0.5 Ppm;
C2h2: 0.1 Ppm;
C2h4: 0.5 Ppm;
C2h6: 0.5 Ppm;
Moisture: 0~100 Ppm;
O2 & N2: Customized;
|