| Specification |
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
IP Rating: IP20;
Customized: Customized;
Outer Casing: Plastic Enclosure;
Rated Current: 100A-6000A;
Rated Output: 333mv, 3V AC RMS or 4V DC(True-RMS);
Output Ripple Factor: 1%;
Response Time: ≤1us;
Power Consumption: 70MW;
Bandwidth: 10Hz to 10kHz;
Power Supply: 5V Only for Output 333mv; or 6-12V or 24VDC;
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated Current;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Output on 0A (Zero Drift): ≤5mv;
Terminal: Terminal(3.81 Interval), 4pin, Rj12 Crystal Head;
Current Sensor: Trc, Mrc, Nrc, Y-Fct;
Applicable Scenario: Connect to Power Meter or PLC;
|
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: SemiConductor Integrated;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: Switching Power Supply;
IP Rating: IP44;
Customized: Customized;
Rated Input: 200/400/800/1000/1500/2000A;
Measuring Range: 0~+4000A;
Supply Voltage: DC +12.0~24V;
Output Current: 4.0+16.0mA;
Power Consumption: 15mA;
Mounting: D40.5mm;
|
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: SemiConductor Integrated;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: Switching Power Supply;
IP Rating: IP44;
Customized: Customized;
Rated Input: 200/400/800/1000/1500/2000A;
Measuring Range: 0~+4000A;
Supply Voltage: DC +12.0~24V;
Output Current: 4.0+16.0mA;
Power Consumption: 15mA;
Mounting: D40.5mm;
|
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: SemiConductor Integrated;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: Switching Power Supply;
IP Rating: IP44;
Customized: Customized;
Rated Input: 200/400/800/1000/1500/2000A;
Measuring Range: 0~+4000A;
Supply Voltage: DC +12.0~24V;
Output Current: 4.0+16.0mA;
Power Consumption: 15mA;
Mounting: D40.5mm;
|
Type: Fault Indicator;
Output Signal Type: Digital Output;
Production Process: Injection;
Material: Plastic;
Accuracy Grade: Response Time: ≤100ms;
Application: Switching Power Supply;
IP Rating: IP65;
Customized: Customized;
Short Circuit Alarm Start Current: 200A-2000A (Allowable Error ±10%);
Ground Fault Start Current: 10A - 100A (Allowable Error ±10%);
Automatic Reset Time: 7 Seconds, 1 Hour, 2 Hours, 24 Hours;
Remote Relay Contact Capacity: 230V/AC-5A,30V/DC-1A;
Static Current of The Whole Machine: ≤ 5μa;
Working Current: 3.6V Lithium Manganese Battery, Capacity 2ah;
Scope of Use: in Systems with Voltage Levels Below 35kv;
|