| Specification |
Installation Type: Duct Type;
Sensing Type: Resistive;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Injection;
Material: Resistive Lithium Chloride;
Measuring Medium: Temperature;
IP Rating: IP68;
Customized: Customized;
Application: AC Ntc Temperature Sensor with 6*50mm Sensor Probe;
B Value: 3270K,3380K,3470K,3550K....;
R Value: 1K,2K,4.7K,5K,10K,15K,20K,30K;
R25 Accuracy: ±1%;
Temperature: -40~+300℃;
Shell Material: Copper, Stainless Steel;
Wire: 28AWG,26AWG;
Connector: Rj11/Rj12 ,3p-2510,USB .;
|
Installation Type: Waterproof Connectors Quick Plugging & Unpluging;
Sensing Type: Ntc Thermistor;
Measuring Medium: Temperature;
IP Rating: IP67/IP68;
Customized: Customized;
Temperature Range: -40℃~180℃;
Nominal Resistance (25℃): 10kΩ, 50kΩ, 100kΩ (10kΩ Is Commonly Used);
Resistance Accuracy: ±1%~±5%;
B Value (25/85℃): 3435K/3950K;
Conductor Material: Fiberglass Braided Sheath;
Conductor Length: 0.3m~3m;
Connector Type: 2p/3p Waterproof Male/Female Connector;
Probe Size: Approx. 8~12mm in Diameter;
|
Installation Type: M3/M4 Ring Terminal (with Screw Mounting);
Sensing Type: Ntc Thermistor;
Measuring Medium: Temperature;
IP Rating: IP40;
Customized: Customized;
Temperature Range: -40℃~200℃;
Nominal Resistance (25℃): 10kΩ, 50kΩ, 100kΩ (10kΩ Is The Mainstream);
Resistance Accuracy: ±1%~±5%;
B Value (25/85℃): 3435K/3950K;
Conductor Material: Fiberglass Braided Sheath;
Conductor Length: 0.2m~2m;
Terminal: M3/M4 Ring Terminal (with Screw Mounting);
|
Installation Type: DIN Rail;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Digital Type;
Production Process: Normal Wirewound;
Material: Resistive Lithium Chloride;
Measuring Medium: Temperature and Humidity;
Customized: Non-Customized;
Temperature Range: -30℃~85℃;
Humidity Range: 0~100%Rh;
Accuracy of Temperature: ±1℃;
Accuracy of Humidity: ±3%Rh;
Transmit Frequency: 5 Min;
Communication Interface: RS485 Modbus-RTU Protocol;
Communication Distance: 500m in Open Area;
Battery Life: 3 Years in 25℃ Environment;
Installation Method: 35mm DIN Rail;
|
Installation Type: bundled;
Sensing Type: Resistive;
Contact: Contact;
Output Signal Type: Digital Type;
Production Process: Integration;
Material: Silica gel;
Measuring Medium: Temperature;
Customized: Customized;
Temperature range: -40℃~+125℃;
Resolution: 0.1℃;
Measurement accuracy: ±1℃;
Acquisition cycle: 10 Second;
Reporting cycle: 1minute;
Alarm threshold: 2℃;
Unlimited frequency: 433M/2.4G;
Transmission distance: 300M/100M;
Power supply: Induction pickup 5A;
Service life: 10years;
Strap material: Beaumont Alloy;
Installation method: Bundle;
Overall Dimension: 25.5mm*21.5mm*11mm;
|