| Specification |
After-sales Service: Online Support;
Warranty: 1year;
Display: Needle;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Conductivity Meter;
Measuring Range: 0.01~20μS/Cm, 0.1~200μS/Cm, 1~2000μS/Cm, 10~20000μ;
Accuracy: ±1%Fs;
Power Consumption: 0.4W (RS485), 1W (Analog);
Power Supply: DC 10~30V (0~10V Voltage Output Requires 24V DC);
Temperature Compensation: -20~+100℃ (Default Compensation Temperature 25℃);
Electrode Wire Length: 5m (10m, 15m, 20m Can Be Customized);
|
After-sales Service: 24 Hours Online Service;
Warranty: 1 Year;
Display: LCD;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Hardness Tester;
Accuracy: ±0.01ppm,±0.1ppm,±1ppm;
Mv Input Range: 0.00-1000.00mv;
Temp. Compensation: PT 1000/Ntc10K;
Temp. Range: -10.0 to +130.0℃;
One Multi Function Relay: Clean/Period Alarm/Error Alarm;
Relay Delay: 0-120 Seconds;
Cleaning Setting: on: 1 to 1000 Seconds, off: 0.1 to 1000.0 Hours;
Capacity: 5A/250VAC,5A/30VDC;
Protection Grade: IP65;
Power Supply: 90 to 260VAC, Power Consumption Less Than 5 Watts;
Current Output Accuracy: ±0.05mA;
|
After-sales Service: 24 Hours Online Service;
Warranty: 1 Year;
Display: LCD;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Hardness Tester;
Accuracy: ±0.01ppm,±0.1ppm,±1ppm;
Mv Input Range: 0.00-1000.00mv;
Temp. Compensation: PT 1000/Ntc10K;
Temp. Range: -10.0 to +130.0℃;
One Multi Function Relay: Clean/Period Alarm/Error Alarm;
Relay Delay: 0-120 Seconds;
Cleaning Setting: on: 1 to 1000 Seconds, off: 0.1 to 1000.0 Hours;
Capacity: 5A/250VAC,5A/30VDC;
Protection Grade: IP65;
Current Output Accuracy: ±0.05mA;
Power Supply: 90 to 260VAC, Power Consumption Less Than 5 Watts;
|
After-sales Service: 24 Hours Online Service;
Warranty: 1 Year;
Display: LCD;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Hardness Tester;
Accuracy: ±0.01ppm,±0.1ppm,±1ppm;
Mv Input Range: 0.00-1000.00mv;
Temp. Compensation: PT 1000/Ntc10K;
Temp. Range: -10.0 to +130.0℃;
One Multi Function Relay: Clean/Period Alarm/Error Alarm;
Relay Delay: 0-120 Seconds;
Cleaning Setting: on: 1 to 1000 Seconds, off: 0.1 to 1000.0 Hours;
Capacity: 5A/250VAC,5A/30VDC;
Protection Grade: IP65;
Current Output Accuracy: ±0.05mA;
Power Supply: 90 to 260VAC, Power Consumption Less Than 5 Watts;
|
After-sales Service: Online;
Warranty: 1 Year;
Display: Digital;
Appliance: Water Test;
Portable: Non Portable;
Type: Conductivity Meter;
Accuracy: 1.5% (Fs);
Size: 48 * 96*100mm;
Model: CCT-3320V;
Customized Support: OEM;
|