| Specification |
Protection: Anti-static;
Installation: Vertical;
Housing: Fibre Glass;
|
Protection: Shock Resistance;
Measurement Type: Three-Phase AC Circuit;
Power Consumption: <=5W;
Address Setting Method: Button Setting;
Contact Capacity: 250VAC/5A, DC30V/5A;
Operating Temperature: -25℃,70℃;
Storage Temperature: -30 °c—80 °c;
Insulation Resistance: Conforms to GB/T 13729-2002 Regulation;
Mean Time Between Failures: 76000 Hours;
Surge Interference: Conforms to GB/T 17626.5 Regulations, Severity Lev;
Electrostatic Discharge Interference: Conforms to GB/T 17626.2 Regulations, Severity Lev;
Ability to Withstand Radio Frequency Ele: Conforms to GB/T 17626.3 Regulations, Severity Lev;
Fast Transient Burst Interference Test: Conforms to GB/T 17626.4 Regulations, Severity Lev;
Damped Oscillatory Magnetic Field Interf: Meets GB/T 17626.10 Regulations, Severity Level 4;
Power Frequency Magnetic Field Interfere: Conforms to GB/17626.8 Regulations, Severity Level;
|
Protection: Shock Resistance;
Power Supply Voltage: AC85~265V/DC100-DC330V Adaptive;
Power Supply Frequency: 50Hz ±2%;
Unit Power Consumption: < 1W;
Measurement Accuracy: Voltage: 0.2 Level Current: 0.2 Level Others: 0.5;
Overload Capacity: AC Voltage Circuit: 2 Times The Rated Voltage Cont;
Communication Interface: Interface Form: RS485 Interface Address: 1~32, 5-D;
Environmental Requirements: Operating Temperature: -25℃ - 60&Ordm;
Power Frequency Withstand Voltage and Im: Withstand Voltage Capability: AC2000V, 1min Surge;
Installation Method: All Are Rail-Mounted, Using 35mm Standard Flat Gu;
Unit Size: Height * Width * Depth: 733668mm (2p Empty Open Si;
|
Protection: Shock Resistance;
Installation: Hanging;
Housing: UPR;
Power Input: 180-250VAC or 180-250VDC,50/60Hz;
Control Output: Transistor: 12-24VDC, 40mA Max. Per Group Relay: 2;
Sampling Voltage (Three-Phase): 20-450VAC (L-L) Other Voltage Levels to Be Customi;
Sampling Current (Three-Phase): 5A or 1A Selectable;
Output Step: up to 15 Banks, Programmable, for Single-Phase or;
Harmonic Measurement Range: 2-50th Harmonic Voltage / 2-50th Harmonic Current;
Temperature Measurement Range: -40℃~+120℃;
Operating and Compensation Modes: Manual/Automatic, Programmable; Subcomplementary,;
Number of Rates: Maximum 16 Groups, Programmable;
Target Cosφ: 0.5 Inductive to 0.5 Capacitive Adjustable;
Protection Class: Front Panel: IP54 Rear Panel: IP30;
Installation Environment: Indoor Installation, Altitude Not Exceeding 2000 M;
Environmental Humidity: Daily Average Not More Than 95%, No Condensation O;
Operating Temperature: -10℃~+60℃;
Overall Dimensions: 144*144*100mm (W*D*H);
|
Protection: Shock Resistance;
Reactance Rate: 6%, 7%, 12%, 14% and Non-Standard Customization;
Low Temperature Rise: ≤70K;
Low Noise: ≤48dB;
Insulation Class: Class H (180°c);
Withstand Voltage: at 1.8in, The Inductance Value Is Not Less Than 0.;
Linearity: at 1.8in, The Inductance Value Is Not Less Than 0.;
Over-Temperature Protection: Nc125°c Temperature Control;
Execution Standards: GB/T1094.6 - 2011 "Reactors" IEC60076 - 6 Reactors;
|