| Specification |
Task: Program;
Structure: Closed-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control, Protection, Monitoring, Measurement;
Condition: New;
Customized: Non-Customized;
Material: Stainless Steel;
Series Name: Rxg Series;
Interface Relay: 1 C/O;
Control Circuit Voltage: 230VAC;
Local Signalling: Flag;
Status LED: with;
[UC] Control Circuit Voltage: 24 V AC;
|
Task: Partial Discharge Testing Machine;
Structure: Combination;
Mathematical Model: Non-Linear;
Signal: Continuous;
Function: Measurement;
Condition: New;
Customized: Customized;
Material: Aluminum Alloy;
Power Supply: AC 220V±10%, 50Hz;
Capacitance range to be tested: 6PF-250μF;
Low terminal: 10kHz, 20 kHz, 40 kHz (optional);
High terminal: 80 kHz, 200 kHz, 300 kHz (optional);
Width of window: adjustable 15-150 degree;
Window position: adjustable 0-170 degree;
PD display: LED 3 1/2 digits;
Voltage meter range: 0-100kV (Can be expanded);
Voltage accuracy: better than ±5% (full scale);
|
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control, Protection, Monitoring, Measurement;
Condition: New;
Customized: Customized;
Material: Plastic housing;
Component: Mechanical Structure Type;
For: Diffused Silicon Pressure Transmitter;
Output Signal Type: Analog Type;
Production Process: Integration;
Material: Stainless Steel;
Wiring Type: Two-Wire;
Measuring Medium: Liquid;
IP Rating: IP68;
Customized: Customized;
Type: Level Transmitter;
Sensor Type: Pressure Sensor;
Pressure: 0~1...1000mH2O;
Over Pressure: 1.5 times the full scale;
Accuracy: 0.5%F.S.;
Long-term Stability: 0.2%FS/year;
Supply: 24VDC(12~30V);
Output: 4-20mADC;
Working Temp: 0~80℃;
Medium Temperature: -30~100℃;
Protection of Shell: IP68;
Electrical Connection: Cable outlet;
|
Task: Program;
Structure: Closed-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control, Protection, Monitoring, Measurement;
Condition: New;
Customized: Customized;
Material: ABS;
Input Voltage: 380V / 660V;
Phase: 3-Phase;
Pump Power: 22kw;
Pump Control: Single Pump Control;
Installation: Standing;
Display: LCD Display;
Main Function: Soft Starter;
Protection: Pump Stalled/Dry Run/Phase Loss Protection;
Control Way: Time Setting/Water Level/Pressure /Drainage;
|
Task: Program;
Structure: Closed-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control, Protection, Monitoring, Measurement;
Condition: New;
Customized: Customized;
Material: ABS;
Input Voltage: 380V / 660V;
Phase: 3-Phase;
Pump Power: 37kw;
Pump Control: Single Pump Control;
Installation: Standing;
Display: LCD Display;
Main Function: Soft Starter;
Protection: Pump Stalled/Dry Run/Phase Loss Protection;
Control Way: Time Setting/Water Level/Pressure /Drainage;
|