| Specification |
After-sales Service: Yes;
Warranty: 2 Years;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Input Voltage: DC0-1000V;
Input Current: Split: 0-75mA; Hall: 0-20mA, 4-20mA, 0-5V, 0-10V;
Accuracy: 0.5 or 1 Grade;
Auxiliary Power: DC24V, DC48V, AC/DC85V-265V;
Interface: RS485, Infraed;
Protocol: Modbus-RTU, Dl/T645-2007;
Switch Value: 2di/2do;
|
After-sales Service: 1 Years;
Warranty: 1 Years;
Display: No Display;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter, Branch Circuit Energy Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Current Input: 333mv Cts, Rogowski Coil;
Product Type: Branch Circuit Monitoring Energy Meter;
Application: Power Analysis and Energy Consumption Monitoring;
Current Sensor: 3 in 1 Current Sensor with Rj12 Port;
Mounting: DIN Rail;
Communication: Modbus RTU, RS485 Port;
Current Range: 50mA--12000A;
Voltage: 0~600VAC;
Frequency Range: 50/60Hz;
Harmonic: 50th Max;
Power Supply: 95 to 265 VAC/110~370VDC;
Wiring Mode: 3pH4w 3pH3w 1pH2w (L-N) 1pH2w(L-L) 1pH3w(L-L-N);
Device Application: Power Analysis, Tariff Meter;
Function: Multi Electric Parameters;
Accuracy: 0.5s;
|
After-sales Service: Yes;
Warranty: 1year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Power Meter;
Customized: Customized;
Accuracy: Active Power: Class1; Reactive Power: Class0.5;
Model: Zm-3D Series;
Frequency: 45~65Hz;
Voltage: AC/DC80V~270V;
Working Temperature: -10'c~+55`C;
Elevation: ≤2500m;
Hole Size: 111×111;76X76;92×92;68×68;;
Application: Energy Management System, Power Monitoring System;
Communication Protocol: Modbus-RTU;RS-485;
Communication Interface: 1X RS-485;
Insulation Resistance: >100 MΩ;
IP Class: IP51;
Operation Temperature: -25℃~55℃;
Power Consumption: <4va;
|
After-sales Service: Yes;
Warranty: 1year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Power Meter;
Customized: Customized;
Accuracy: Active Power: Class1; Reactive Power: Class0.5;
Model: Zm-3D Series;
Frequency: 45~65Hz;
Voltage: AC/DC80V~270V;
Working Temperature: -10'c~+55`C;
Elevation: ≤2500m;
Hole Size: 111×111;76X76;92×92;68×68;;
Application: Energy Management System, Power Monitoring System;
Communication Protocol: Modbus-RTU;RS-485;
Communication Interface: 1X RS-485;
Insulation Resistance: >100 MΩ;
IP Class: IP51;
Operation Temperature: -25℃~55℃;
Power Consumption: <4va;
|
Display: Indicator;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Type: Power Meter;
Customized: Customized;
Type of Current Sensor: Rogowski Coilvoltage-Output Current Transformer;
Poles Description: 3p4w_3CT, 3p3w_3CT, 3p3w_2CT, 1p3w, 1p2;
Frequency Range: 50/60Hz;
Application: Current,Voltage,Power,Energy and Harmonic Measurem;
Current Sensor Type: Rogowski Coil;
Advantage: Wide Current Range, Measurement Without Dismantlin;
Primary Rated Current: 5A, 100A, 600A, 2500A, 6000A;
Secondary Rated Input: 100mv/Ka@50Hz, 50mv/Ka@50Hz, 85mv/Ka@50Hz;
Recommended Sensor: STP CT, STP Rogowski Coils;
Voltage Range: 0~600VAC Phase to Phase Voltage;
Communication: Modbus RTU, RS485 Port;
Power Supply: 5VDC;
Maximum Power Consumption: 3.5va;
Data Refresh Rate: 500ms;
Measurement Range: 0~600VAC;
|