| Specification |
Type: Electromagnetic;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Metal;
Accuracy Grade: 0.5G;
Application: Ad, DSP, PLC, Energy Meter;
IP Rating: IP40;
Customized: Customized;
Input Current: AC or DC;
Primary Input Current: 0-20000A;
Secondary Output Current: 4-20mA, 5V, 4V;
Auxiliary Power: +12V/15V/24V, -12V/15V/24V;
|
Type: Integrator/Amplifier/Converter/Transducer;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 1% Typical at 1%(≥10A) to 200% of Rated;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP68;
Customized: Customized;
Outer Casing: Waterproof Plastic Enclosure;
Rated Output: 4-20mA DC or 333mv;
Power Consumption: 100MW;
Bandwidth: 30Hz to 1kHz;
Power Supply: 12V or 24V DC;
Rated Input: 100A-6000A;
Output Wire: 0.5 Meter 4PCS Wires;
Response Time: Default 100ms(Adjustable);
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Minimum Current Measurement: 1A (Ripple 100mA);
Operating Temperature: -20℃ to 70℃;
Current Sensor: Rogowski Coil Y-Fct, Trc;
Applicable Scenario: Combine with Power Meter or PLC;
|
Type: Integrator/Amplifier/Converter/Transducer;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 1% Typical at 1%(≥10A) to 200% of Rated;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP68;
Customized: Customized;
Outer Casing: Waterproof Plastic Enclosure;
Rated Output: 4-20mA DC or 333mv;
Power Consumption: 100MW;
Bandwidth: 30Hz to 1kHz;
Power Supply: 12V or 24V DC;
Rated Input: 100A-6000A;
Output Wire: 0.5 Meter 4PCS Wires;
Response Time: Default 100ms(Adjustable);
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Minimum Current Measurement: 1A (Ripple 100mA);
Operating Temperature: -20℃ to 70℃;
Current Sensor: Rogowski Coil Y-Fct, Trc;
Applicable Scenario: Combine with Power Meter or PLC;
|
Type: Integrator/Amplifier/Converter/Transducer;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 1% Typical at 1%(≥10A) to 200% of Rated;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP68;
Customized: Customized;
Outer Casing: Waterproof Plastic Enclosure;
Rated Output: 4-20mA DC or 333mv;
Power Consumption: 100MW;
Bandwidth: 30Hz to 1kHz;
Power Supply: 12V or 24V DC;
Rated Input: 100A-6000A;
Output Wire: 0.5 Meter 4PCS Wires;
Response Time: Default 100ms(Adjustable);
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Minimum Current Measurement: 1A (Ripple 100mA);
Operating Temperature: -20℃ to 70℃;
Current Sensor: Rogowski Coil Y-Fct, Trc;
Applicable Scenario: Combine with Power Meter or PLC;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: Switching Power Supply;
IP Rating: IP67;
Customized: Customized;
Window Size: 100, 150, 200mm;
Reference Rated Current: 1000A, 3000A, 6000A;
Coil Resistance: From 260 to 390Ω;
|