| Specification |
After-sales Service: One Year;
Principle: RF Admittance;
Range: 3.9" to 118 "(100 to 3000mm);
Measurement Accuracy: Conductive: ± 2mm, insulating: ± 20mm;
Kind: Level Switch;
Structure: All in One;
Warranty: 1 Year;
Material: 316LSST, 304SST, 316SST, Titanium, 304LSST, etc.;
Process Temperature: -112~851℉(-80~455℃);
Measurement Parameters: Liquid level, material level;
Housing Structure: Single Chamber;
Housing Material: High pressure cast aluminum or stainless steel;
Dielectric Constant: ≥2;
Medium Viscosity: ≤0.4Pa·S;
Cable Entry: 3/4"NPT;
Output Voltage: 24VDC or 220VAC, with polarity reversal protection;
Power Consumption: 1W;
Ambient Temperature: -40~176℉(-40~80℃);
Storage Temperature: -40~176℉(-40~80℃);
Humidity: 0~100% Relative humidity;
Operation Pressure: 0~63bar(0~6.3MPa);
Probe Rod Outer Diameter: 0.3 "(8mm);
Damping: 2 Seconds;
Process Display: LED red/blue indication;
|
After-sales Service: Yes;
Principle: Radar;
Range: 0-20m;
Measurement Accuracy: ±5mm;
Accuracy: 0.2%;
Kind: Radar;
Structure: All in One;
Warranty: 3 Year;
Material: PC;
Process Temperature: -40°-80°;
Feature 1: Wireless;
Feature 2: Non-Contact Measurement;
Function 1: Water Level Detector;
Function 2: Water Level Meter;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|