| Specification |
Type: Laser light scattering method;
Warranty: 1 Year;
Sample Flow Rate: 2.83L/min±5% (0.1CFM);
Particle Size Channels: 0.3μm,0.5μm,1.0μm,2.5(3.0)μm,5.0μm,10.0μm;
Vacuum Supply: Built-in vacuum pump;
Calibration Standard: GB/T6167-2007, JJF1190-2008;
Repeatability Error: below ±5%;
Size Distribution Error: below ±5%;
Cleanliness Test Range: Class100 ~ Class1,000,000; Max conc.:35,000pcs/L;
Communication: RS485, Modbus RTU Protocol;
Power Supply: DC24V;
Housing: Metal casing;
Temp & Humidity Module: Optional;
Operating Condition: Temp:0℃~50℃; Humidity:20%~95%;
Sample Gas: Free of acid, alkali & corrosive gas;
Storage Condition: Temp:-10℃~50℃; Humidity:0%~98%;
|
Type: Static Laser;
Sample Feeding: Dry and Wet;
Warranty: 2 Years;
Model: Nkt-N9;
Execution Standard: 29022-2012/ISO;
Measurement Range: 1-10000nm(Related with The Samples);
Concentration Range: 0.1mg/L-100mg/L;
Scattering Angle: 90;
Sample Chamber: 10mm*10mm, 4ml;
|
Type: Static Laser;
Sample Feeding: Dry and Wet;
Warranty: 2 Years;
Model: Nkt-N9;
Execution Standard: 29022-2012/ISO;
Measurement Range: 1-10000nm(Related with The Samples);
Concentration Range: 0.1mg/L-100mg/L;
Scattering Angle: 90;
Sample Chamber: 10mm*10mm, 4ml;
|
Type: Static Laser;
Sample Feeding: Wet Dispersion;
Warranty: 2 Years;
Meansure Range: 0.5-780um;
Optical Path Calibration: Automatic;
Channels Number: 66;
Executive Standard: ISO 13320- 1:1999/ GB/T19077. 1-2008;
Application: Nasal Drug Products/Aerosol Research;
Reference Particle Size: D90/D50/D10;
Measurement Range Option: 0.5micron - 780 Microns;
Repeatably Error: <1% (Average Particle Size of National Standard S;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 1 Minutes;
Operation Temperature: 0-45 Degree;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
Weight: 48kgs;
|
Type: Static Laser;
Sample Feeding: Wet Dispersion;
Warranty: 2 Years;
Meansure Range: 0.5-780um;
Optical Path Calibration: Automatic;
Channels Number: 66;
Executive Standard: ISO 13320- 1:1999/ GB/T19077. 1-2008;
Application: Nasal Drug Products/Aerosol Research;
Reference Particle Size: D90/D50/D10;
Measurement Range Option: 0.5micron - 780 Microns;
Repeatably Error: <1% (Average Particle Size of National Standard S;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 1 Minutes;
Operation Temperature: 0-45 Degree;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
Weight: 48kgs;
|