| Specification |
After-sales Service: 1 Year;
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Diesel Fuel, Fuel Oil;
Size: DN100-500;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Volume Type Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Inlet & Outlet: 150mm/6 Inch;
Flow Range: 300-3000L/M;
Volume Per Revolution: 14.87L;
Max. Pressure: 10bar;
Repeataility: ≤0.7%;
Standard Measurement: Liter/Us Gallon/Imp Gallon;
Gross Weight: 180kg;
|
After-sales Service: Factory Warranty and Timely Online Instruction;
Warranty: 12 Months;
Accuracy: ±0.2-0.5%;
Main Application: Water, Diesel Fuel, Fuel Oil;
Size: DN2-DN40;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Volume Type Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Pressure Difference;
Measurement Object: Closed Pipeline;
Material: SUS304 or Aluminum Alloy;
Temp.: -20-80℃ or Customized;
Pressure: 1.6MPa;
Measuring: High Viscosity Liquid;
Power: 24VDC and 3.6V Lithuim Battery;
Protection Grade: IP65;
Output: Pulse/4-20mA/RS485;
Display: LCD Display;
Connection: Flange, Thread, Tri-Clamp;
Explosion-Proof: Ex Db Iic T6 GB;
|
After-sales Service: Within 24 Hours;
Warranty: on Year;
Accuracy: 1.0%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Size: DN25-DN2000;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Faraday's Law of Induction;
Measurement Object: Closed Pipeline;
Module: Hart and Fieldbus (FF) Terminal;
Display: LCD;
Power: 24V DC;
Output: 4-20mA;
Measuring Tube: Austenitic Stainless Steel;
Communication Protocol: Hart + FF Dual Protocol;
Liner: PFA,Polypropylene (PP), Hard Rubberptfe, PFA, ETFE;
Measuring Electrodes: Hastelloy C,Stainless Steel, Titanium;
Process Connections: En 1092-1 ;ASME ;JIS;
|
After-sales Service: Within 24 Hours;
Warranty: on Year;
Accuracy: 1.0%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Size: DN25-DN2000;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Faraday's Law of Induction;
Measurement Object: Closed Pipeline;
Module: Hart and Fieldbus (FF) Terminal;
Display: LCD;
Power: 24V DC;
Output: 4-20mA;
Measuring Tube: Austenitic Stainless Steel;
Communication Protocol: Hart + FF Dual Protocol;
Liner: PFA,Polypropylene (PP), Hard Rubberptfe, PFA, ETFE;
Measuring Electrodes: Hastelloy C,Stainless Steel, Titanium;
Process Connections: En 1092-1 ;ASME ;JIS;
|
After-sales Service: Offer After-Sales Service;
Warranty: 1 Year;
Accuracy: ±0.10%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN10-50;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Open Channel;
Outputs: 4-20mA;
Hazardous Area Certs: ATEX, Iecex, FM, CSA;
Ingress Protection: IP66;
Flow Tube: 316L Stainless Steel;
Measured Variables: Mass Flow;
Temperature Accuracy: ±0.5°C;
Ambient Temperature Range: -40°C to +60°C;
Rangedown: up to 200:1;
Measurement Range: up to 1000 Inh2o;
Line Size: 2 to 96 in;
Communication Protocol: 4-20 Ma Hart®, Wirelesshart®, Foundation™ Fieldbus;
Update Rate: 1 Sec. to 60 Min., User Selectable;
Process Wetted Material: 316 Sst, Alloy C-276;
Applications: Steam, Gas, Liquid Flow Measurement; Energy Flow;;
Model: 3051sfa;
|