| Specification |
Application: Electronic, Instrument, Electricity Meter;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement, Electricity Meter;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy Class: 0.05, 0.1, 0.2;
Application Range: Energy Meter;
Max Current: 5A-300A;
Current Transformer Ratio: 1:1000, 1:2000, 1:2500;
DC Immunity: DC Immunity;
Material: Nano Crystalline, Ferrite Core;
Self Heating Testing: Pass Self Heating Testing;
DC Tolerance: Good DC Tolerance;
Standard: IEC62052-31;
Rosh: Rosh Compliant;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Keyword: 10kv Current Transformer;
Model: 10kv Outdoors CT Current Transformer;
Rated Primary Current (a): 10-1500A;
Accuracy Class: 0.2s, 0.5s;
Surface Creepage Distance (mm): 460;
Wt (Kg): 23;
Color: Red/Gray;
|
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Fu-16: Plit Core Current Transformer;
Ratio: 1000: 1 or 2000:1 , Customized;
Overload Withstand: 1.2 Times Rated Current Continuously;
Accuracy: 0.2%, 0.5 %, 1%;
System Voltage: 720V(0.72kv);
Weight (G): 60;
Operating Temperature: -25 to +55°c;
Relative Humidity: 0-85% Non-Condensing;
Altitude: <3500 Meters;
Output: Standard 2.5 Meter Cable;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Ratio: 1000: 1 or 2000:1 (Customized);
Accuracy Class: 0.2%, 0.5%, 1%;
Primary Current: 0 - 3000A AC;
Secondary Current: 0 - 5A AC (Customized);
Max. Cont. Input Current: 3600A;
Over Voltage Category: Cat III 600 V;
Output Signal (AC Current): 500mA,1A,5A AC at Nominal Input Current;
Output Signal (AC Voltage): 333mv,500mv,1V,5V AC at Nominal Input Current;
Weight (G): 1100;
Holding Wire Diameter (mm): φ125;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Ratio: 1000: 1 or 2000:1 (Customized);
Accuracy Class: 0.2%, 0.5%, 1%;
Primary Current: 0 - 3000A AC;
Secondary Current: 0 - 5A AC (Customized);
Max. Cont. Input Current: 3600A;
Over Voltage Category: Cat III 600 V;
Output Signal (AC Current): 500mA, 1A, 5A AC at Nominal Input Current;
Output Signal (AC Voltage): 333mv, 500mv, 1V, 5V AC at Nominal Input Current;
Weight (G): 1700;
Holding Wire Diameter (mm): φ150;
|