| Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: ACB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Number of Pole: 1;
Main Circuit Rating Current: 630A;
Phase: 1/2/3;
Main Circuit Rating Voltage: 12KV;
Name: Vacuum Interrupter;
Shelf life: 20years;
Color: Silver, Copper;
Afterserivce: Yes;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: MCB;
Poles Number: 1,2,3,4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection;
Rated Current in: 6,10,16,25,32,40,50,63,80,100,125A;
Poles: 1,2,3,4;
Rated Voltage Ue: 230/400V;
Rated Frequency: 50/60Hz;
Electrical Life: 4000t;
Mechanical Life: 10000t;
Protection Degree: IP20;
Connection: From Top and Bottom;
Short-Circuit Breaking Capacity: 6000A;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: DIN Rail;
Poles Number: 1,2,3,4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, 1,2,3,4;
Rated Current in(a): 1,2,3,4,6,10,16,20,25,32,40,50,63;
Rated Operational Voltage(Ue): DC400 DC800 DC1000 DC1200 DC1500;
Number of Poles: 1,2,3,4,;
Installation Method: DIN35 Standard Rail;
Breaking Capacity ICU: 6ka/10ka;
Protection Degree: IP20;
Electrical Life (Times): 1500;
Mechanical Life (Times): 20000;
Standard: IEC60947-2;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: DIN Rail;
Poles Number: 1,2,3,4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, 1,2,3,4;
Rated Current in(a): 1,2,3,4,6,10,16,20,25,32,40,50,63;
Rated Operational Voltage(Ue): DC400 DC800 DC1000 DC1200 DC1500;
Number of Poles: 1,2,3,4,;
Installation Method: DIN35 Standard Rail;
Breaking Capacity ICU: 6ka/10ka;
Protection Degree: IP20;
Electrical Life (Times): 1500;
Mechanical Life (Times): 20000;
Standard: IEC60947-2;
|