| Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Primary Input: 0.25A~150A;
Lead Time: 7-15 Working Days;
Output: 0.333va/0-5VAC/Ma;
Core: Ferrite;
Turns Ratio: Customizable;
|
Application: Electronic, Instrument, Power System;
Type: Combined Transformer;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage Ratio: 20000/100V;
Rated Current Ratio: 5-200/5A;
Accuracy Classes: 0.2-0.5;
Rated Output: 10-50va;
Limit Output: 500va;
Rated Insulation: 42/95/195kv;
Rated Short Time Thermal Current: 100lin;
|
Application: Electronic, Instrument, Power System;
Type: Combined Instrument Transformers Measuring Box;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Primary Current: 7.5-1000A;
Rated Frequency: 50/60Hz;
Rated Voltage: 35kv 10kv 6kv;
Accuracy Level: 0.2s-10 0.5s-10 0.5-15;
Rated Transformation Ratio: Voltage Ratio: 6000/100V 10000/100V;
Univariate Ratio: 7.5-1000;
Rated Secondary Output: 10-15va;
One Second Thermal Stability Current: 1.0-80ka;
Dynamic Stable Current: 2.5-100ka;
Max Output: 2*400va;
Rated Insulation Level: 7.2-75kv;
Single Transformer Ratio: 7.5-1000;
|
Application: Electronic;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Model: Sct2851 Series Current Transformer 13mm;
Is_Customized: Yes;
Rated Input: 75A-800A;
Short-Time Thermal Current: 60in;
Secondary: 1A,5A;
Class: 0.5,0.2,0.5s,0.2s;
Rated Test Voltage: 3kv AC(1 Min);
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Product Name: Current Transformer;
Model: H-DCT028;
Rate Current: 10A;
Max Current: 60A;
Secondary Current: 4mA;
Winding Ratio: 1:2500;
Burden Resistance: 12.4 Ohm;
Cable Length: 80mm;
Wire No: 2;
Net Weight: Approx 28g;
ODM: Customization;
OEM: Customization;
Anti Mangnetic: Yes;
RoHS: Customization;
Supply: Jiaxing Haihan Electron Co., Ltd;
|