| Specification |
Accuracy: 0.2%-1.0%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN80-2000;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Vortex Flow Meter;
Measuring Media: Liquid;
Measurement Object: Closed Pipeline;
Process Temperature: -80~180°C;
Ambient Temperature: -40~80°C;-20~60°Cwith LCD;
Range: 0.67~885nm3/H;
Flange Standard: ANSI;
Flange Material: 316L;
Flange Size: ANSI 2"150RF;
Body Material: Aluminum;
Element Material: 316L;
Mounting Style: Integral;
Power Supper: 24VDC;
Output Signal: 4-20mA;
Output Indicator: Yes;
Electrica Connect: 1/2"NPT;
Explosion Proof: Ex Ia Iict4;
Pressure: 0-420bar;
|
After-sales Service: by Video;
Warranty: 1 Year;
Accuracy: ≤±0.1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN8-DN80;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid and Gas;
Measuring Principle: Atomic Physics;
Measurement Object: Closed Pipeline;
|
After-sales Service: by Video;
Warranty: 1 Year;
Accuracy: ≤±0.1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN8-DN50;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid and Gas;
Measuring Principle: Atomic Physics;
Measurement Object: Closed Pipeline;
|
After-sales Service: Changing or Refunding;
Warranty: 1 Year;
Accuracy: >±1%;
Main Application: Water, Wastewater, Nature Gas, Corrosive Liquid/Gas, Steam;
Size: DN15~DN300 or Above;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Vortex Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Karman Vortex Street;
Measurement Object: Closed Pipeline;
Medium Temperature: -40 ℃ ~ 350 ℃;
Ambient Temperature: -20 ℃ ~ 70 ℃;
Pressure Rating: 1.6MPa, 2.5MPa, 4.0MPa, 6.3MPa, or Customized;
Body Material: SS304, SS316, etc.;
Connection Way: Flange, Clamp, Insertion, Threaded, etc.;
|
After-sales Service: Changing or Refunding;
Warranty: 1 Year;
Accuracy: >±1%;
Main Application: Corrosive Liquid/Gas, All Gases Except Acetylene;
Size: DN10~DN2000;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Probe Type Flow Meter;
Measuring Media: Gas;
Measuring Principle: Thermodynamic;
Measurement Object: Closed Pipeline;
Medium Temperature: ≤150℃; 0~200℃; 0~300℃;
Pressure Rating: <2MPa; <10MPa;
Probe Material: SS304, SS316L, 1Cr18Ni9Ti;
Structure: Split Type, Integrated Type;
Connection Way: Insertion, Flange;
|