| Specification |
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry, Aquaculture,Swimming Pool,Wastewater,Surface Water;
Portable: Non Portable;
Type: Conductivity Meter;
Measure Range: 0~20ms/Cm; 0~200ms/Cm;
Accuracy: ±2%Fs;
Cell Constant: K = 10.0;
Resolution: 0.01ms/Cm;
Temperature: 0~60°C;
Temperature Compensation: Automatic;
Output Signal: RS485, 4~20mA;
Pressure: 0~4bar;
Shell: PPS;
Thread: G3/4, NPT3/4;
Install: Immersion Type/Pipeline;
Cable: 5m or Cutomized;
Working Conditions: Power Supply DC 9~30V, Humidity <90%;
Ingress Protection: IP68;
Detection Limit: 0.1ms/Cm;
|
After-sales Service: 24-Hour Customer Service;
Warranty: 1 Year,1 Year;
Display: Digital;
Appliance: Sewage Treatment;
Portable: Portable;
Type: Liquid Analyzer;
Usage: Industrial, Agriculture;
Product Model: HG CN S100;
Country of Origin: Nanjing;
Repeatability: ≤±5%;
Accuracy: ≤±10%;
Environmental requirements: +5~28°C;
Sampling period: (20~9999) min;
Detection range: (0~2)mg/L, extended;
Communication Interface: RS485/RS232, (4~20)mA;
Texture: Galvanized sheet + Powder coating;
Detection method: Isonicotinic acid - barbituric acid spectrophotome;
|
After-sales Service: 24-Hour Customer Service;
Warranty: One Year;
Display: Digital;
Appliance: Sewage Treatment;
Portable: Portable;
Type: Liquid Analyzer;
Usage: Industrial, Agriculture;
Product model: HG PO4 S100;
Customization: Available;
Repeatability error: ±10%;
Zero drift: ±5%;
Range drift: ±10%;
Linearity: ±10%;
Measurement range: (0 - 300) mg/L (expandable);
Power: 150 W (excluding water pump);
Power supply voltage: AC (220 ± 10%) V; (50 ± 10%) Hz;
Texture: Galvanized sheet + Powder coating;
|
After-sales Service: 24-Hour Customer Service;
Warranty: 1 Year;
Display: Digital;
Appliance: Sewage Treatment;
Portable: Portable;
Type: Liquid Analyzer;
Usage: Industrial, Agriculture;
Product Model: HG LSY S100;
Display value error: ±10%;
Repeatability: ±5%;
Range Drift: ±5%F.S;
Zero point drift: ±5%F.S;
Measurement cycle: (20~30) min;
Detection range: (10~50)mg/L, extended;
Communication interface: RS485/RS232, (4~20)mA;
Texture: Galvanized sheet + Powder coating;
|
After-sales Service: 24-Hour Customer Service;
Warranty: 1 Year;
Display: Digital;
Appliance: Sewage Treatment;
Portable: Portable;
Type: Liquid Analyzer;
Usage: Industrial, Agriculture;
Product Model: HG LSY S100;
Display value error: ±10%;
Repeatability: ±5%;
Range Drift: ±5%F.S;
Zero point drift: ±5%F.S;
Measurement cycle: (20~30) min;
Detection range: (10~50)mg/L, extended;
Communication interface: RS485/RS232, (4~20)mA;
Texture: Galvanized sheet + Powder coating;
|