| Specification |
After-sales Service: Yes;
Warranty: 3 Years;
Application: CT PT Tester;
Power: Electricity;
Voltage Output: 0-120V;
Current Output: 0-5A;
Thermocouple (TC): R;
LCD Display: With LCD Display;
Customized: Customized;
Name: CT PT Analyzer;
Theory: DC Variable-Frequency Methods;
Usage: Measurement CT and Protection C;
Phase Error: 1min or 3min;
Ratio Error: 0.02% or 0.05%;
CT Raito: 1-50000;
PT Ratio: 1-10000;
Weight: 4kg;
|
After-sales Service: 24 Hours Online Service;
Warranty: 3 Years;
Application: Electromagnetic Instrument, CT Calibration;
Voltage Output: 0~180vrms;
Current Output: 12arms,36A(Peak Value);
Thermocouple (TC): N/a;
LCD Display: With LCD Display;
Customized: Non-Customized;
Connection Port: 2 USB2.0 Ports, 1 Communication Port;
Testing Method: Secondary Injects Low Test Signals;
Calibration Acuracy: 0.05%;
Testing Object: CT and PT;
Knee Voltage Measuring Range: >30kv;
PC Operation: Avaliable;
CT Turns Ratio Test: 1~40000, Precision ±0.05%;
PT Turns Ratio Test: 1~40000, Precision ±0.1%;
Model: ISO, SGS;
|
After-sales Service: 24 Hours Online Service;
Warranty: 3 Years;
Application: Electromagnetic Instrument, CT Calibration;
Voltage Output: 0~180vrms;
Current Output: 12arms,36A(Peak Value);
Thermocouple (TC): N/a;
LCD Display: With LCD Display;
Customized: Non-Customized;
Connection Port: 2 USB2.0 Ports, 1 Communication Port;
Testing Method: Secondary Injects Low Test Signals;
Calibration Acuracy: 0.05%;
Testing Object: CT and PT;
Knee Voltage Measuring Range: >30kv;
PC Operation: Avaliable;
CT Turns Ratio Test: 1~40000, Precision ±0.05%;
PT Turns Ratio Test: 1~40000, Precision ±0.1%;
Model: ISO, SGS;
|
After-sales Service: Lifetime Technical Support;
Warranty: 1 Year for Calibration Set for Cable Fault Locator;
Application: Cable Fault Detection Instrument Verification Tool;
Power: Electricity;
LCD Display: With LCD Display;
Customized: Customized;
Product Name: Cable Fault Detection Instrument Calibrator;
Test Standard: IEC 61010;
Power Supply: 220V±5V, 50Hz ±0.5Hz;
Wave Speed Setting Range: 100m/Us~300m/Us;
Fault Reflection Waveform Peak: 0.5~2V;
Fault Reflection Waveform Selection: Square Wave, Sine Wave;
|
After-sales Service: 24 Hours Online Service;
Warranty: 3 Years;
Application: Electromagnetic Instrument, CT Calibration;
Voltage Output: 0~180vrms;
Current Output: 12arms,36A(Peak Value);
Thermocouple (TC): N/a;
LCD Display: With LCD Display;
Customized: Non-Customized;
Connection Port: 2 USB2.0 Ports, 1 Communication Port;
Testing Method: Secondary Injects Low Test Signals;
Calibration Acuracy: 0.05%;
Testing Object: CT and PT;
Knee Voltage Measuring Range: >30kv;
PC Operation: Avaliable;
CT Turns Ratio Test: 1~40000, Precision ±0.05%;
PT Turns Ratio Test: 1~40000, Precision ±0.1%;
Model: ISO, SGS;
|