| Specification |
After-sales Service: Yes;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: No;
Gaspath System: No;
Detector: UV;
Energy Resolution: 2%;
Spectrometer Detector: UV;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 250mm-500mm;
Chromatographic Column Diameter: ID10-20mm;
Weight: 160kg;
After Sales Service: Support;
Installtion Video: Yes;
Injection Mode: Manual(Autosampler as Option);
Auto Sampler: Yes;
Fraction Collector: Yes;
FDA 21 Part Complaice: Yes;
Power: 220V,60Hz,750kw;
Control Mode: Software Control;
Max Pressure Dosing Pump: 30MPa;
UV: 190-700nm;
Flow Rate: 0.01-49.99ml/Min;
Fraction Racket: Bottles or Tubes as Option;
Collection Consition: Time/Threshold/Shope;
Columns: ID10/20/30 as Option;
|
Injector Specification: 1,5,25,50,100,250,500(Units:UL);
Sample Turret: 160 Sample Vials;
Times for Each Line Injection: 1-99;
Minimum Injection: 0.1UL;
Maximum Injection: 500UL;
|
After-sales Service: Yes;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Single;
Detector: FID;
Spectrometer Detector: Si(Li);
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 2~5mm;
Operation Display: 5.7 Inch Lattice Localization Color LCD;
Temperature Control Region: 6 Road;
Temperature Range: Above Room Temperature 8 Degrees~ 450degree;
Incremental: 1 Degree;
Accuracy: + / - 0.1 Degree;
Temperature Programmed Order Number: 16 Order;
Cheng Sheng Rate: 0.1~39 Degrees/Min;
Gas Control: Mechanical Valve Control Mode, Electronic Flow Con;
External Event: 4 Way; Auxiliary Control Output 4 Road.;
Boot Into The Sample: Manual, Automatic Optional;
|
After-sales Service: Yes;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Single;
Detector: FID;
Spectrometer Detector: Si(Li);
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 2~5mm;
Operation Display: 5.7 Inch Lattice Localization Color LCD;
Temperature Control Region: 6 Road;
Temperature Range: Above Room Temperature 8 Degrees~ 450degree;
Incremental: 1 Degree;
Accuracy: + / - 0.1 Degree;
Temperature Programmed Order Number: 16 Order;
Cheng Sheng Rate: 0.1~39 Degrees/Min;
Gas Control: Mechanical Valve Control Mode, Electronic Flow Con;
External Event: 4 Way; Auxiliary Control Output 4 Road.;
Boot Into The Sample: Manual, Automatic Optional;
|
After-sales Service: Life Time Support Service;
Warranty: 1 Year for Transformer Oil Chromatograph Analysis;
Appliance: Transformer Oil Chromatograph Analysis;
Gaspath System: Double;
Detector: FID;
Chromatography Type: Gas Chromatography;
Test Item: Transformer Oil Chromatograph Analysis;
Key Word: Transformer Oil Gas Chromatography;
Test Standard: IEC 60599/ASTM D3612;
Power Supply: AC 220V±10%, 50Hz/60Hz;
Power: <500W;
Small Automatic Oscillator: 1 Set;
|