| Specification |
After-sales Service: 1 Year;
Warranty: 1 Year;
Appliance: Delivery Solvent;
Ray Type: No;
Gaspath System: No;
Detector: UV;
Energy Resolution: 1%;
Spectrometer Detector: Si(Li);
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 50mm-1000mm;
Chromatographic Column Diameter: ID50mm;
Power Supply: 24VDC;
Flow Rate Increment: 0.1 Ml/Min;
Binary Gradient Accuracy: ±1%;
Flow Rate Accuracy: ±1%;
Maintence Sop: Yes;
Outlet: 1/8;Od2mm ID PTFE Piping;
Inlet: 1/16;
High Precisely: Yes;
Demension: 220*110*226mm;
Control by Software: Yes;
Pump Head: 316L;
Communication Protocol: Yes;
Check Valve: Yes;
Work-up Kit Provided: Yes;
Customized: Yes;
|
After-sales Service: Online;
Warranty: 1years;
Appliance: Laboratory;
Ray Type: Contact;
Gaspath System: Contact;
Detector: Contact;
Energy Resolution: ≤7.5%;
Spectrometer Detector: Contact;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: Contact;
Chromatographic Column Diameter: Contact;
USP: G2,G3,G16,G19,G25,G26,G36,G43,G46;
High Efficiency Capillary: on-1,on-5,on-1701,on-Wax,on-Ffap,on-17,on-225.;
Specialty Capillary: for Tvoc,Pestcides I, Pestcides II,Pona,Amine,etc.;
Function: for Chromatography;
Feature: Laboratory;
MOQ: 1PCS;
|
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Three;
Detector: MSD;
Energy Resolution: ≤7%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Max Pressure: 35MPa;
Flow Rate Range: 0.001 -- 10.000ml/Min;
Qualitative Repeatability: 0.5%;
Quantitative Repeatability: 1.0%;
Pressure Display Accuracy: ≤0.01MPa;
|
Warranty: 1 Year;
Appliance: Medical Research;
Gaspath System: Three;
Detector: MSD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Working Power: 220V, 50Hz;
Maximum Pump Pressure: 62MPa/75MPa;
Flow Setting Range: 0.0001-12.0000ml/Min;
Flow Rate Setting Increment: 0.0001ml/Min;
Gradient Error: ≤0.75%;
|
After-sales Service: Online;
Warranty: 1years;
Appliance: Laboratory;
Ray Type: Contact;
Gaspath System: Contact;
Detector: Contact;
Energy Resolution: ≤7.5%;
Spectrometer Detector: Contact;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: Contact;
Chromatographic Column Diameter: Contact;
USP: G2,G3,G16,G19,G25,G26,G36,G43,G46;
High Efficiency Capillary: on-1,on-5,on-1701,on-Wax,on-Ffap,on-17,on-225.;
Specialty Capillary: for Tvoc,Pestcides I, Pestcides II,Pona,Amine,etc.;
Function: for Chromatography;
Feature: Laboratory;
MOQ: 1PCS;
|