| Specification |
After-sales Service: Online Technical Support, Onsite Installation, Ons;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Protection Level: IP67;
Precision: 0.1%;
|
Appliance: The Analysis of Environmental Samples;
Ray Type: No;
Gaspath System: Single;
Detector: FID;
Energy Resolution: ≤8%;
Spectrometer Detector: SDD;
Stationary Phase: Gas;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 0.2~0.5mm;
|
After-sales Service: Free of Charge;
Warranty: 18 Months;
Appliance: Biochemistry;
Ray Type: /;
Gaspath System: /;
Detector: FID;
Energy Resolution: /;
Spectrometer Detector: /;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: /;
Chromatographic Column Length: /;
Chromatographic Column Diameter: /;
High Pressure Constant Flow Pump: 1 Set;
Flow Pump Flow Rate Range: 0.001ml/Min-10.000ml/Min;
Flow Accuracy: ≤±0.2% (1.00ml/Min, H2O, R.T., 8.5MPa);
Flow Precision: Rsd≤0.075% (1.00ml/Min, H2O, R.T., 8.5MPa);
Maximum Pressure: 45MPa;
Pressure Accuracy: ≤±3.0%;
|
Appliance: Medical Research;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Three;
Detector: FID;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
|
After-sales Service: Online;
Warranty: 1 Year;
Appliance: Biochemistry;
Ray Type: Gas Chromatograph;
Gaspath System: Single;
Detector: FID;
Energy Resolution: ≤7%;
Spectrometer Detector: Tcd;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 2~5mm;
Oven Temp. Range: Rt+5℃~400℃;
Oven Temp. Accuracy: ±0.02℃;
Oven Temp. Program: 9-Phase/ 10 Platform;
Oven Max Temp. Heating Rate: 60℃/Min;
Sample Injector Temp. Range: Rt+7℃~420℃;
Detector Temp. Range: Rt+7℃~420℃;
Power Supply: Power Supply;
Standard Accessory: Fid Detector, Capillary Injection System, Chromato;
Optional Accessory: Tcd Detector, Chromatographic Column, Gas Purifier;
Package Size (W*D*H): 1020*660*740mm;
Gross Weight: 82kg;
|