| Specification |
After-sales Service: Life Long Support;
Warranty: 1 Year;
Type: Transformer Turns Ratio Tester;
Accuracy Grade: 0.2;
Display: LCD;
Weight: 10kg;
Power Source: AC220V;
Transformer Ratio: 1--10000;
Group: 1--12 Point (12 Vector Groups);
Environment Temperature: -5--40;
Humidity: <85%;
|
After-sales Service: Life Long Support;
Warranty: 1 Year;
Type: Transformer Turns Ratio Tester;
Transformer Ratio: 1--10000;
Group: 1--12 Point (12 Vector Groups);
Environment Temperature: -5--40;
Humidity: <85%;
Standard: IEC;
Range of Measurement: 0.9~10000;
Resolution: Minimum 0.0001;
Accuracy: 0.2 Level;
Output Voltage: 120 V;
Working Power: AC 220V±10%;
Supply Frequency: 50Hz/60Hz;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|
After-sales Service: Life Long Support;
Warranty: 1 Year;
Type: Transformer Turns Ratio Tester;
Transformer Ratio: 1--10000;
Group: 1--12 Point (12 Vector Groups);
Environment Temperature: -5--40;
Humidity: <85%;
Standard: IEC;
Range of Measurement: 0.9~10000;
Resolution: Minimum 0.0001;
Accuracy: 0.2 Level;
Output Voltage: 120 V;
Working Power: AC 220V±10%;
Supply Frequency: 50Hz/60Hz;
|