| Specification |
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year or Extended;
Type: CT/PT Analyzer;
Accuracy Grade: 0.2%;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: <9kg;
Power Source: AC220V;
Usage: Class P/Tp CT & Vt;
Output: 0~100vrms,12arms,36A(Peak Value);
Voltage Measurement Accuracy: ±0.2%;
CT Ratio: Range:1~30000;Accuracy:±0.2%;
PT Ratio: Range:1~10000;Accuracy:±0.2%;
Phase: Range:±5min;Accuracy:0.5min;
DC Resistance: Range:0~300Ω;Accuracy:2%±2mΩ;
Burden: Range:0~300va;Accuracy:2%±0.2va;
Standard: IEC;
Model Name: CT Analyzer;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: at Customized;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: at Customized;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
|
After-sales Service: Life Long Support;
Warranty: 1 Year;
Type: Partial Discharge Detector;
Power Source: AC220V;
Product Name: Partial Discharge Detector;
Channel: 4;
Sensitivity: 0.1PC;
Measurement Band: 3dB Bandwidth of 10kHz-1000kHz;
Lp: 10K,20K,40K,80K;
HP: 100K,200K,300K,1000K;
Gain Range: -20 dB ∽ +40 dB Fourth Gear;
Sampling Accuracy: 12bit;
Sample Rate: 10m /Sec.;
External Voltage Monitoring: RMS Voltage, 14-Bit a / D Accuracy;
Synchronization: Internal and External Optional, External Synchroni;
Sync Input Range: 10V --- 220V;
Linearity Error of The Range Stalls: Less Than 5% ± 1PC;
|
After-sales Service: Suppor for Lifelong;
Warranty: 2 Year;
Type: Relay Tester;
Display: Digital;
Control: Computer Control;
Weight: 20kgs;
Power Source: AC220V;
Accuracy of Measurement: <0.1ms;
Phase Voltage / Line Phase Output Power: 80va / 100va;
Harmonic Time: 0-20;
Frequency Range (Fundamental): 0-1000Hz;
Output Precision: 0.5 Degree;
Time Measuring Range: 0.1ms - 9999s;
Product Name: Relay Tester;
Model Type: Hmjbc-802;
Support PC: Windows 10, Winidows7,XP;
Frequency: 50Hz/60Hz;
Input Voltage: 220V or 120V;
Phase: 3 Phase, 6 Phase or Sinlge Phase;
Applicated: Relay Tester;
Calibration Report: Factory Release Calibration Report or Third Party;
|