| Specification |
Type: Silicon Piezoresistive Type;
Structure Design: Input Type;
Pressure Range: Atmospheric pressure;
Display Type: LED LCD No Display;
Accuracy Grade: 0.5G;
IP Rating: IP68;
Customized: Customized;
Measuring Range: 0-20m;
Connecting Type: Terminal Blocks;
|
Customized: Customized;
Range: 3, 5, 8, 10, 12, 15, 20, 25, 30m(Customizable);
Power Supply: DC12-30V;
Output: 4-20mA.0-5V.0-10vrs485;
Beam Angle: <12°;
Ingress Protection: Default IP65 (Other Options Customizable);
Blind Area: 0.25~1.5m (According to Different Range);
Housing: ABS, PVC;
Consumption: <1.5W;
Selling Units: Single Item;
Single Package Size: 25X11.6X12.5cm;
Single Gross Weight: 1.500kg;
Frequency: 20 kHz~43.0kHz;
Warranty: 1 Year;
Explosion Proof: Exiall Bt4GB;
Customized Support: OEM,ODM,Obm;
|
Type: Silicon Piezoresistive Type;
Structure Design: Input Type;
Pressure Range: Atmospheric pressure;
Display Type: Dial;
Accuracy Grade: 1.0G;
IP Rating: IP65;
Customized: Customized;
Power Supply: PVDC;
Measure Range: 0-500m;
Medium Temp: -20 to 80°C;
Measurement Object: Liquid Fuel Oil Water;
Keywords: Portable Steel Ruler Deep Water Level Meter;
|
Type: Silicon Piezoresistive Type;
Structure Design: Input Type;
Pressure Range: High Pressure;
Display Type: LCD;
IP Rating: IP68;
Customized: Customized;
Measuring Range: 0-10kpa...3.0MPa;
Overload: 1.5 Times Pressure Range of Full Scale;
Protection Level: IP68;
Accuracy: ±0.25%Fs(Typical); ±0.1%Fs(Optional);
Output Signal/Power Supply(Option1): 2-Wire 4~20madc / Vs=10~30 VDC;
Output Signal/Power Supply(Option2): 2-Wire 0~10V etc./ Vs=12~32 VDC;
Output Signal/Power Supply(Option3): 3-Wire 0~5V etc. /Vs=10~30 VDC;
Output Signal/Power Supply(Option4): 3-Wire 0.25~1.25V, 0.5~2.5V etc. / Vs=2.8~5.5VDC;
Output Signal/Power Supply(Option5): 4-Wire Modbus-RTU/RS485 / Vs=10~30 VDC;
Medium Temperature: -20-85℃;
|
Type: Liquid Level Transmitter;
Structure Design: Rigid Lead, Flexible Lead;
Pressure Range: 0~250bar(0~25MPa);
Display Type: LCD;
Accuracy Grade: ±0.1%;
IP Rating: IP67/IP68;
Customized: Customized;
Measurement Principle: Capacitance and admittance measurement method;
Measurement Parameters: Liquid level/inerface, material level;
Housing Structure: Dual Chamber;
Housing Material: High pressure cast aluminum, stainless steel;
Cable Entry: 1/2"NPT or M20×1.5;
Dielectric Constant: ≥2.0;
Input Voltage: 13.5~30VDC, with polarity reversal protection;
Output Signal: 2-wire 4~20mADC, HART;
Operation Temperature: -112~788℉(-80~420℃);
Ambient Temperature: -40~176℉(-40~80℃);
Humidity: 0~100% Relative humidity;
Process Display: 4~20mA, percentage, program unit;
Output Unit: ft, in, m, cm, mm;
Load destruction: 3755 pounds(17kN);
Thread: 3/4"NPT;
|