| Specification |
After-sales Service: 24-Hour Online After-Sales Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Double;
Detector: FID;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Power Supply: AC220V±10%, 50Hz;
Optional Accessory: 500ml Solvent Bottle*2, Column, Column Oven;
Workstation: Elitapex *1;
Flow Rate: 0.001~10.000ml/Min(Step: 0.001ml/Min);
Accuracy: ≤+0.3%;
Precision: ≤0.1%Rsd;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: Medical Research;
Gaspath System: Double;
Detector: UV-Vis Dual-Wavelength Detector;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Flow Range: 0.001-10ml/Min(Set Step 0.001ml/Min);
Flow Accuracy: ≤±0.25%(0.001-10ml/Min);
Flow Precision: Rsd<0.05%;
Working Pressure: 30.0 MPa;
Gradient: 2 or 3;
Dimension: 400mm*300mm*180mm;
Power Supply: AC 110V/220V,50Hz/60Hz;
Material: Peek;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: Food Analysis;
Gaspath System: Double;
Detector: UV-Vis Dual-Wavelength Detector;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 680mm;
Chromatographic Column Diameter: 200mm;
Infusion Mode: Dual Plunger in Series;
Flow Range: 0.01-300ml/Min(Set The Step Size to 0.001ml/M;
Flow Accuracy: ≤±0.15%;
Flow Precision: Rsd<0.1%;
Working Pressure: 10MPa;
Control Mode: RS232 or LAN;
Power: 150W;
Material: 316L;
|
After-sales Service: Provided;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Detector: Fid, Tcd, Ecd, Fpd, Npd, Pid;
Chromatography Type: Gas Chromatography;
Temperature Range: 7℃ ~ 400℃;
Program Ramps: 7;
Program Setting: 0.1℃~40℃/Min;
Increment: 0.1℃;
Total Time of Total Program: up to 655 Minutes;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Double;
Detector: FID;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Control Range: Room Temperature +5 ~400℃;
Accuracy: ±0.1℃;
Programmed Temperature Ramp: 8;
Heating Rate: 0.1°~-40℃/Min;
Actual Temperature Error: <0.5℃;
Maximum Operation Temperature: 400℃;
Application: Wastewater, Chemical, Pharmaceutical, Hospital, Fo;
|