| Specification |
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤8%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Model: Bk-Lci5100;
Type: Isocratic Pump;
Flow Rate Range: 0.001-10.000ml/Min, in;
Flow Accuracy: ≤±0.2% (1.00ml/Min, H2O,R.T.,8.5MPa);
Flow Precision: Rsd≤0.06% (1.00ml/Min, H2O,R.T.,8.5MPa);
Maximum Pressure: 63MPa;
Pressure Accuracy: ≤±3.0%;
Pressure Pulsation: ≤0.1MPa;
Wavelength Range: 190-800nm;
Wavelength Repeatability: ≤0.1nm;
Wavelength Accuracy: ≤±1.0nm;
Band Width: 6nm;
Response Time: 0.0s-5s;
Baseline Noise: ≤±0.25×10-5au(Empty Cell254nm, 1.;
Drift: ≤0.5×10-4au/H(Empty Cell,, 60min);
|
After-sales Service: Online Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: X-Ray Spectrometer;
Gaspath System: Double;
Detector: Silicon Photodiode;
Energy Resolution: ≤8%;
Spectrometer Detector: Si(Li);
Chromatographic Column Diameter: 1~2mm;
Optical System: Single Beam, Grating 1200 Lines/mm;
Wavelength Range: 190~1100nm;
Spectral Bandwidth: 2nm;
Wavelength Accuracy: 0.5nm;
Wavelength Repeatability: Less Than 0.3nm;
Stability: 0.001A / H @ 500nm;
Baseline Flatness: 0.002A;
Noise: 0.0005A;
Display: 480 * 272 65 Thousand True Color TFT LCD;
Photometric Mode: T, a, C, E;
Photometric Range: 0~200% T, -0.301~3.0A;
Light Source: Lamp, Tungsten Lamp;
Input: Membrane Keypad;
Output: USB Print and Data Output, Connect PC;
Gross Weight(Kg): 18;
|
After-sales Service: Provided;
Warranty: 1 Year;
Detector: Fid, Tcd, Ecd, Fpd, Npd, Pid;
Chromatography Type: Gas Chromatography;
Temperature Range: 7℃ ~ 400℃;
Program Ramps: 7;
Program Setting: 0.1℃~40℃/Min;
Increment: 0.1℃;
Total Time of Total Program: up to 655 Minutes;
|
After-sales Service: 24-Hour Online After-Sales Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Double;
Detector: FID;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Max. Temp. Heating Rate: 40℃/Min;
Temp. Accuracy: ≤±0.1℃;
Temp. Program: 20-Phase;
Time Range: 0-655min;
|
After-sales Service: 24 Hours on Line Service;
Warranty: 12 Month;
Appliance: /;
Ray Type: /;
Gaspath System: /;
Detector: /;
Energy Resolution: /;
Spectrometer Detector: /;
Stationary Phase: /;
Mobile Phase: /;
Chromatography Type: /;
Chromatographic Column Type: /;
Chromatographic Column Length: /;
Chromatographic Column Diameter: /;
Product Name: Gas Chromatograph;
Oven Temp. Range: Rt+5℃~400℃;
Pre Column Pressure Range: 0-400kpa;
Oven Capacity: 22L;
Sample Injector Max. Quantity: 3PCS;
|