| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ACB;
Poles Number: 3 & 4;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Insulation Voltage: AC 1000V;
Rated Impulse Withstand Voltage: 8000V;
Frequency Measurement Range: 45.00~55.00Hz;
Lock Function: Via The RS485II Interface;
Clock Error: ≤ 0.5 S/Day;
Measurement Accuracy: Voltage: ≤ 0.5%; Current: ≤ 0.5%; Power: ≤ 1%;
Overcurrent Protection: Electronic Three-Stage Overcurrent Protection;
Frame Size Options: 160 a , 250 a ; 400 a, 630 a (Under Development);
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Standard: BS 7671 2008;
Compliance: BS En 61439-3;
Material: Aluminum Iron;
Protection Class: IP65;
Warranty: 10 Years;
Packaging: Carton+Pallet;
Accessory: Circuit Breaker, Neutral Block, Cable Gland;
Terminal Block: Brass Gland Plate;
Application: Light Pole,Street Light,Cable Distribution;
Earthing Device: Earth Shrouded Neutral Block;
Capacity: in Stock;
Color: Grey Ral Standard;
Zinc: Hot DIP Galvanized;
Isolator: MCB Isolator;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Voltage Ui: 500V AC;
Rated Current: 2,4,6,10, 16, 20, 25, 32, 40, 50, 63A;
Frame Current: 63A;
Rated Working Voltage: Normal and High Voltage;
Poles: 1-4p;
Rated Insulation Voltage Ui: 1200V;
Rated Umpulse Withstand Voltage Uimp: 6kv;
Tripping Curve: B, C, D, K;
Tripping Characteristics: B/C;
Tripping Type: Thermal Magnetic;
Electrical Durability: 2000 Cycles;
Mechanical Durability: 20000cycles;
Overvoltage Category: Three;
Pollution Degree: 3;
Ingree Protection: IP40, Wiring Port IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage Ue: DC 1000, 1500V;
Rated Insulation Voltage Ui: DC 1600V;
Frame Current: 320, 400, 630u;
Poles: 2/3 Poles;
Tripping: Electromagnetic Tripping+ Thermal Tripping;
Rated Impulse Withstand Voltage Uimp: 12kv;
Ultinate Short-Circuit Breaking Capacity: 20ka;
Ambient Temperature: -35℃~+70℃;
Mechanical Durability: 15000/10000/5000;
Electrical Durability: 2000/1500/700;
Standard: IEC/En 60947-2, GB/T 14048.2;
Certificates: CCC, CB, CE, TUV;
Utilization Category: a;
Isolation Function: Have;
Size(L/W/H) mm: 200*80*135(2p), 200*114*135(3p), 270*125*169;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Installation: Fixed;
Type: Circuit Breaker;
Function: Overcurrent Protection;
|