| Specification |
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Double;
Detector: UV-Vis Dual-Wavelength Detector;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 680mm;
Chromatographic Column Diameter: 200mm;
Product Name: Xzlc-2050 Ultra-High Pressure Liquid Chromatograph;
Set Step Size: 0.001ml/Min~5ml/Min;
Flow Accuracy: ≤±0.25%(0.001-5ml/Min);
Maximum Working Pressure: 100MPa;
Display Pressure Error: <±0.5 MPa(0~100MPa);
Pressure Pulsation: <0.1%;
Pump Sealing: Pressure: 42 MPa; Duration: 10 Min; Pressure Drop:;
Flow Precision: Rsd<0.05%;
Gradient: Binary or Trivariate;
Power Supply: AC 110V/220V, 50Hz/60Hz;
Uvd Detector: UV-Vis Dual Wavelength Detector;
Linear Range: 2.8au(5%);
Wavelength Range: 190-700nm Increments of 1nm;
Wavelength Repeatability: ±0.1nm;
Wavelength Accuracy: ±1nm;
|
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: FID;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Gel Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 10~20cm;
Chromatographic Column Diameter: 0.2~0.5mm;
Model: Bk-UV1800;
Optical System: Single Beam, Grating 1200 Lines/mm;
Wavelength Range: 190~1100nm;
Spectral Bandwidth: 2nm;
Wavelength Accuracy: ± 0.5nm;
Photometric Accuracy: ± 0.002A (0~0.5ABS);
Stray Light: ≤ 0.05% T @ 360nm;
Stability: ± 0.001A / H @ 500nm;
Power Supply: AC110V/220±10% ,60/50Hz;
Packing Size(mm): 620*500*370;
|
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: UV/Vis Spectrophotometer;
Gaspath System: Double;
Spectrometer Detector: Si(Li);
Optical System: Double Beam, Grating 1200 Lines/mm;
Wavelength Range: 190~1100nm;
Spectral Range: 1.8nm;
Wavelength Accuracy: ±0.3nm;
Wavelength Repeatability: ≤0.2nm;
Photometric Accuracy: ±0.002A(0~0.5ABS), ±0.004A(0.5~1.0ABS), ±0.3%T(0~1;
Stray Light: ≤0.04t@360nm; 220nm;
Stability: ±0.0003A/H@500nm;
Baseline Flatness: ±0.0005A;
Noise: ±0.0002ABS;
Photometric Mode: T, a, C, E;
Photometric Range: 0~200%T, -0.301~3.0A;
Light Source: Tungsten Lamp;
Input: Membrane Keypad;
Gross Weight: 25kg;
|
After-sales Service: on Line Service;
Warranty: One Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: X-Ray Spectrometer;
Gaspath System: Three;
Detector: MSD;
Energy Resolution: ≤7.5%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~20cm;
Chromatographic Column Diameter: 0.2~0.5mm;
Power: 220 V, 50 Hz;
Temperature: 15-35c;
Humidity: 25%-80% Rh;
Column Oven Temperature: Room Temperature + 10c-400c;
Temperature Stability: <=-+0.03c;
Maximum Heating Rate: 40c/Min;
Maximum Run Time: 999.99 Min;
Pressure Range: 0-999 Kpa;
Flow Range: 0-200 Ml/Min;
Mass Range: 1.5-1024 Amu;
Mass Stability: Better Than 0.1 Amu/48 H;
Resolution: Unit Mass;
Maximum Scan Rate: 10,000 Amu/S;
Dynamic Range: 105;
Maximum Filament Current: 3 a;
|
After-sales Service: on Line Service;
Warranty: One Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: X-Ray Spectrometer;
Gaspath System: Three;
Detector: FPD;
Energy Resolution: ≤8%;
Spectrometer Detector: SDD;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 1~2mm;
Column Oven: Rt+5c up to 400c;
Column Temp Accuracy: Set Value (K) +-0.5%;
Temp. Deviation: 2 C Max;
Mass Scope: 1.5 - 1024 Amu;
Mass Resolution: >1.5m;
Electron Multiplier: 0-3kv;
Two Scan Modes: Scan and SIM;
Mechanical Pump: 2 L/S;
Syringe Specification: 1,5,10,25,50,100,250,500 UL;
Method Type: 20;
Maximum Quantity: 500 UL;
Minimum Quantity: 0.1 UL;
Time Distance for Each Injection: 0-9999s;
Times for Each Line Injection: 1-99 Times;
Sample Tray Specification: 110 Digit Sample Tray (or 15 Digit Sample Tray);
|