| Specification |
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Double;
Detector: UV-Vis Dual-Wavelength Detector;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 680mm;
Chromatographic Column Diameter: 200mm;
Product Name: LC8500 High-Pressure Infusion Pump with Uvd8500 De;
Set Step Size: 0.01ml/Min;
Infusion Mode: Parallel Dual Pistons;
Flow Rate Range: (0~499.99)Ml/Min;
Maximum Working Pressure: 15MPa;
Flow Rate Accuracy: ±0.5%;
Reproducibility Rsd (Stability): 0.3%;
Control Mode: RS232 or LAN;
Overall Dimensions: 488*380*215(L*W*H);
Display: 5.6-Inch Touchscreen;
Power: 750W;
Height: 27.2kg;
Uvd Detector: Uvd8500 UV-Vis Dual Wavelength Detector;
Bandwidth: 8nm;
Wavelength Accuracy: ±1nm;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Appliance: /;
Ray Type: /;
Gaspath System: /;
Detector: /;
Energy Resolution: /;
Spectrometer Detector: Si(Li);
Chromatographic Column Length: /;
Chromatographic Column Diameter: /;
Flow Rangein): 0.1-0999.9ml/Min,Flow Increment of 0.1ml/Min;
Max Pressure: 10MPa;
Flow Accuracy: 1%;
Flow Rate Precisiol: Rsd≤0.5%;
Pressure Fluctuatic: ≤0.2MPa;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Appliance: Oil Analysis;
Ray Type: No;
Gaspath System: No;
Detector: LED;
Energy Resolution: 1%;
Spectrometer Detector: No;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: No;
Chromatographic Column Type: No;
Chromatographic Column Length: No;
Chromatographic Column Diameter: No;
Weight: 4.5kg;
Sample Volume: 50-150UL;
Short Measurement Time: Within 3min;
Full Automated Measure: Yes;
Osmolality Range: 0-2000mosmol/Kg;
Presision: Rsd Less 4mosmol/Kg;Rsd Less 1%(400-2000mosmol/Kg);
Linearity: +-1.5%;
Calibration: Two-Point Calibration;Optional:Three-Point;
Interface: RS-232 Port;
Control: Keypad;
Power Supply: 100-240V,50-60Hz,70W;
Demension: 16-*182*320mm;
Ambient Conditions: 10-35 Degree,20-80% Relative Humudity;
|
After-sales Service: 1 Year;
Warranty: 2 Years;
Appliance: Other;
Ray Type: Not Applicable;
Gaspath System: Double;
Detector: TCD;
Energy Resolution: Not Applicable;
Spectrometer Detector: 0;
Stationary Phase: Capillary Column;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: Other;
Chromatographic Column Diameter: Other;
Temperature Range: Ambient +3°C to 399°C;
Temperature Control Precision: ±0.1°C;
Temperature Accuracy: ±3%;
Cooling Speed: 250°C to 50°C in Approximately 8 Minutes;
9-Step Program;
|
After-sales Service: 1 Year;
Warranty: 2 Years;
Appliance: Other;
Ray Type: Not Applicable;
Gaspath System: Double;
Detector: TCD;
Energy Resolution: Not Applicable;
Spectrometer Detector: 0;
Stationary Phase: Capillary Column;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: Other;
Chromatographic Column Diameter: Other;
Display: 7-Inch Color Touchscreen;
Temperature Control Zones: 8;
Temperature Range: Ambient +4°C to 450°C;
Temperature Accuracy: ±0.1°C;
Temperature Increment: 0.5°C;
Temperature Program: 16-Step Programming;
Detector Capacity: up to 3 Detectors;
Detector Types: Fid, Tcd, Ecd, Fpd, Npd;
Injection Types: Packed Column, Capillary Column, Six-Port Valve, a;
Sampling Mode: Manual / Automatic;
External Events: 8 Channels;
Auxiliary Outputs: 2 Channels;
Communication Interface: Ethernet IEEE802.3;
Data Acquisition: 24-Bit High-Resolution a/D;
Protocol Support: Modbus/TCP;
|