| Specification |
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Double;
Detector: FID;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Control Range: Room Temperature +5 ~400℃;
Accuracy: ±0.1℃;
Programmed Temperature Ramp: 8;
Heating Rate: 0.1°~-40℃/Min;
Actual Temperature Error: <0.5℃;
Maximum Operation Temperature: 400℃;
Application: Wastewater, Chemical, Pharmaceutical, Hospital, Fo;
|
After-sales Service: Online Service;
Warranty: 1year;
Appliance: The Analysis of Environmental Samples;
Ray Type: /;
Gaspath System: /;
Detector: /;
Energy Resolution: /;
Spectrometer Detector: UV;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 1~2mm;
Temperature Range: Ambient Temperature +7℃ ~ 400℃;
Temperature Accuracy: ± 0.02℃;
Cooling Time: 400℃ to 50℃ in 8-10 Min;
Programmed Temperature Setting: 0.1℃~40℃/Min (in 1℃ Increment);
Detection Limit: ≤3×10-12g/S (C16);
Best Test Result: ≤3×10-12g/S (C16);
Drift: ≤6×10-13A/30min;
Noise: ≤5×10-14A;
Linearity Range: ≥106;
Sensitivity: ≥5000mv, Ml/Mg (C16);
Baseline Noise: ≤20µV;
Detector Drift: ≤60µV/H;
Detector Linearity Range: ≥104;
|
After-sales Service: Response on Customers' Questions Within 12 Hours.;
Warranty: 12 Months;
Appliance: Transformer Oil;
Ray Type: Gas Chromatograph;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 0.2~0.5mm;
Gas Detection: H2, CH4, C2h4, C2h6, C2h2, Co, CO2, H2O;
Referemce Standard: IEC61850;
Description: Oil Dissolved Gas Analyzer Gas Chromatograph;
Communication Serial Port: 2 RS48;
Environment Temperature: -40 ~+55 Degree;
Relative Humidity: 5%~95%;
Atmospheric Pressure: 80kpa~110kp;
Altitude: 0~3000m;
Dimension: 1400*720*420mm;
Gross Weight: 292kg;
Language: English;
OEM Service: Available;
|
After-sales Service: 1year;
Warranty: 1year;
Appliance: Analysis furans;
Ray Type: UV Vis;
Gaspath System: Liquid flow system;
Detector: UV Detector;
Energy Resolution: ≤7%;
Spectrometer Detector: UV Detector;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: C18;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 0.2~0.5mm;
|
After-sales Service: 24/7. All Time Zones Friendly;
Warranty: 1year;
Appliance: Transformer Oil;
Gaspath System: Three;
Detector: TCD and FID;
Energy Resolution: ≤7%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 0.2~0.5mm;
Product Name: Oil Gas Chromatograph;
Voltage Range: 0.5~10kv;
Test Current Range: 10μa~1A;
Power Factor: 0.02 < Cos φ < 0.1;
Current Range: 0.5A ~ 15A (Internal), 0.5A ~ 50A (External);
Frequency Measuremen: 45 ~ 65Hz;
Ambient Temperature: -10°c to 50°c;
Ambient Humidity: ≤85℅rh, Non-Condensing;
Operating Power Supply: AC220V ±10%;
Use: Testing the Gas Analysis;
|