| Specification |
After-sales Service: 24 Hours Online Service;
Warranty: 1 Year;
Display: LCD;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Online Turbidimeter;
Weight: 1.65 Kg;
High Voltage Baffle: Aviation Connector, Cable Connector;
Warranty Period: 1 Year;
Cable Length: Standard 10-Meter Cable, Max Length: 100 Meters;
Calibration: Sample Calibration, Slope Calibration;
Environment Temperature: 0~45℃;
Flow Velocity: <2.5m/S,8.2FT/S;
Pressure Range: ≤0.4MPa;
Measurement Range: 0.01-100 Ntu ,0.01-4000 Ntu;
|
After-sales Service: Online Service;
Warranty: 12months;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Portable;
Type: Toc Analyzer;
Model: Toc-1700;
Detection Mode: Online;
Detection Range: 0.001-1.5mg/1;
Detection Limit: 1ppb;
Max Tolerance: ±5%;
Analysis Time: 3 Min;
Response Time: Within 10 Min;
Sample Temperature: 1-95°c;
Environment Temperature: 10-40°c with Temperature Change ±5;
Sample Flow Speed: 3ml/Min;
Relative Humidity: ≤85%;
Drifting: ±5%;
Rated Power: 100W;
Frequency: 50/60Hz;
Power Supply: AC 220V, 50/60Hz or AC 110V, 50/50Hz;
|
After-sales Service: Online Service;
Warranty: 12months;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Portable;
Type: Toc Analyzer;
Model: Toc-5000;
Method: High Temperature Combustion;
Detector: Ndir;
Parameters: Tc, Tic, Toc, Npoc;
Operation Mode: PC Software Controlled;
Application: Liquid Sample;
Gas Requirement: Oxygen≥99.995%;
Measurement Range: 0-30000mg/L;
Power Supply: AC 220V/AC 110V, 50/60Hz, 1kw;
Dimension: 450X500X 480mm;
|
After-sales Service: warranty;
Warranty: 1 Year;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry, Water;
Portable: Non Portable;
Type: Digital Fluorescence Dissolved Oxygen Sensor;
Resolution: 0.01mg/L;
Accuracy: ±0.3mg/L;
Calibration Cycle: 6 months;
Protection Level: IP68;
MTBF: ≥1440h/time;
Power Consumption: <1W;
Zero Drift: ±0.3mg/L;
|
After-sales Service: 3 Years;
Warranty: 3 Years;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry, E. Coli Analyzer;
Portable: Non Portable;
Type: Concentration Meter;
Name: E. Coli Analyzer;
Model: Wtf5600-Colitech;
Analysis Range: 1mpn/100ml to 230mpn/ 100ml (Range Expandable);
Detection Limit: 1mpn/100ml;
Culture Temperature: 36℃ or 44℃;
Sampling Frequency: Regular 24-Hour Automatic Sampling (Adjustable);
Measurement Period: The Maximum Measurement Cycle Is 24 Hours;
Weight: 60kg;
Power Supply: AC 220V ± 10%, 50Hz ± 1%;
Water Temperature: 5—35℃;
|