Basic Info.
Application
High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Principle of Work
Vector Control Transducer
Switch Mode
High Carrier Frequency PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Transport Package
Standard Export Packing
Specification
380V 56/60Hz
Product Description
Product Overview:
SJR3-2000 series is the latest soft starter developed by our factory. It expands new functions such as literal display, industrial communication and various protections based on the products of SJR2 series. This product will be the upgrading and replacement of SJR2 series eventually. It shares the same technical framework with SJR3-3000.
The applicable standards:IEC 60947-2-2:2002
Product Features:
(1) Easy to control: support a variety of communication protocols; operation panel can be used outside ; programmable output; 4-20mA DC analog output.
(2) Long life:compared to intense heating, heavy harmonic pollution and high module consumption caused by online module, this type of soft starter has a longer using life and more safety.
(3) Liquid crystal display: this display is more intuitive and convenient.
(4) No need for control circuitry: it greatly slashes the material cost.
(5) Space saving: compared with star-delta starter and self coupling decompression starter, the built-in bypass greatly reduces space requirement for the cabinet, so the user can arrange the electrical equipment in higher density, thereby reducing the cost.
(6) Labor saving: compared with star-delta starter and self coupling decompression starter, greatly cut down the design and installation time for no need of deploying line circuitry.
Specifications
Electrical Parameters
| Standards | Compliance with the international standard: IEC 60947-2-2;2002 |
| Three-phase power supply | Voltage(AC) 380V±15% (220V and 660V optional ) |
| Frequency | 50Hz/60Hz |
| Applicable motor | Squirrel cage three-phase asynchronous motor |
| Starting frequency | When the motor is fully loaded, it shall not start more than 4 times per hour; Less than 10 times per hour with no or little load. |
| Protective class | IP20 |
| Anti shock | accorded with IEC68-2-27:15g,11ms |
| Seismic capacity | Vibration intensity is 0.5G or less at an altitude less than 3000 meters. |
| Ambient temperature | The capacity needn't be reduced when the working temperature is between 60ºC C and 40ºC (At the temperature between 40ºC and 60ºC, the current should be decreased 2% whenever the temperature is 1ºC higher.) |
| Storage temperature | -25ºC~70ºC |
| Ambient moisture | 93%, no condensation or drip, in line with IEC68-2-3 |
| Maximum working | The capacity will not be reduced when the working height is less than 1000 meters (If is higher than 1000 meters, the current will be decreased 5% whenever it is 100 meters higher.) |
| Cooling means | Natural cold wind |
| Installation Angle | Vertical installation and the angle of tilt should be in the range of±10°. |
Reference for application fields
| Application of mechanical type | load type | The executive ability of SJR3 | Starting current % | Starting time (second) |
| Centrifugal pump | Standard load | Slow shutdown protection (to eliminate water hammer), under-load protection or protection against phase inversion. | 300 | 5-15 |
| Piston pump | Standard load | Run test. Control of no-lubrication run and pump rotation direction. | 350 | 5-15 |
| Fan | Standard load, heavy load if>30S | Having detected overload or under load caused by blockage, it will provides braking torque. (click on fan to interrupt drive) | 300 | 10-40 |
| Shrink machine | Standard load | Motor protection, the motor can also provide special | 300 | 5-10 |
| Screw compressor | Standard load | Provides protection against phase reversal, and is used for automatic discharge of contact when the machine is stopped. | 350 | 3-20 |
| Centrifugal compressor | Standard load, heavy load if>30S | Provides protection against phase reversal, and is used for automatic discharge of contact when the machine is stopped. | 300 | 10-40 |
| Piston compressor | Standard load | Provides protection against phase reversal, and is used for automatic discharge of contact when the machine is stopped. | 350 | 5-10 |
| the transmission belt / transmission machine | Standard load | The process control of fault detection or the under-load control of the circuit | 350 | 3-10 |
| Spiral crane | Standard load | Overload control of harsh environment detection | 300 | 3-10 |
| T- cable car | Standard load | Overload control of blockage detection | 300 | 2-10 |
| Elevator | Standard load | Overload control of blockage detection. Constant start of varying load. | 400 | 5-10 |
| Saw / band | Standard load | Fast stop brake | 300-350 | 5-60 |
| Crusher / Chip cutting machine | Heavy load | Control starting torque | 400 | 3-10 |
| Blender | Standard load | Current display, indication of product density | 350 | 5-20 |
| Mixer | Standard load | Current display | 350 | 5-10 |
| Lapping machine | Heavy load | The vibration is limited when the machine is stopped. Overload control of blockage detection. | 450 | 5-60 |
Crushing machine | Standard load | The vibration is limited when the machine is stopped. Overload control of blockage detection. | 400 | 10-40 |
Refining machine | Standard load | Control starting and stop torque. | 300 | 5-30 |
| Press | Heavy load | Increase working cycle brake | 400 | 20-60 |
Tracting lift | Standard load | Overload control of blockage detection or under load control for the detection of breakpoints | 400 | 2-10 |
Lifting screw | Standard load | Overload control of blockage detection or under load control for the detection of breakpoints | 300 | 3-10 |
Tracting lift | Standard load | Overload control of blockage detection or under load control for the detection of breakpoints | 400 | 2-10 |
Lifting screw | Standard load | Overload control of blockage detection or under load control for the detection of breakpoints | 300 | 3-10 |
Specifications
| Function names | Setting range | Illustrations |
| Starting voltage | 40%-70% | 40% the voltage when voltage ramp mode is effective. |
| Soft starting time | 2-60s | Current limit mode is invalid. |
| Soft stop time | 2-60s | Free park when set to 0. |
| Starting delay | 0-999s | Adopts countdown for starting delay mode.. Start when it is set to 0. |
| Program delay | 0-999s | Operating relay output (03, 04 terminals). Close immediately when the set is 0. |
| Interval delay | 0-999s | Overheating is also delayed. The state indicator flashes in the delay period. |
| Starting current limit | 50-500% | 400% The current limit mode is effective, and the maximum value in voltage ramp mode is 400% |
| Maximum working current | 50-200% | Percentage of the motor' rated current . |
| Faceplate display means | | English display |
| Under voltage protection | 40%-90% | Activate protection when it is lower than the set value. |
| Over voltage protection | 100%-140% | Activate protection when it is higher than the set value. |
| Starting mode | 00-05 | 00 current limit ; 01 voltage; 02 snap-through + current limit; 03 snap-through + voltage;04 current ramp ; 05 double closed loop ; 06 prohibited |
| Output protection permit | 00-04 | 00 Junior;01 light load;02 standard;03heavy load;04 senior |
| Operation control means | 00-06 | set to 0 for keyboard operation. Further information, refer to manufacture instructions. |
The function list of the terminal
| Classification | Mark of the terminal | Terminal Name | Function Descriptions |
Contact output | L1,N | Power input | AC220V control power input (live line, neutral line) to the control panel. |
| 01,02 | Run input (delay) | Bypass output (spare terminal under SJR3-3000). |
| 03,04 | Run output (delay) | 03, 04 programmable relay output, delay time set by the code F4., Output functional time set by the code FE . (AC250V/3A) |
Contact input | 07 | Transient input | Disconnect 07 and 10 , the motor will stop immediately (or connected in series to the normally closed point of the thermal relay) |
| 08 | Soft stop input | Disconnect 07 and 08, the motor will execute deceleration and soft stop. (or it stops by itself) |
| 09 | Start input | Connect 09 and 10, the motor execute start to start operation |
| 10 | Common port | the contact is connected to the common port |
Analog output | 11,12 | Analog output | 11, 12: 4~20mA DC analog output for real-time monitoring of motor current. When it is full 20mA and the indicated current of the motor is 4 times the rated current of the soft starter, it can connect externally to a 4-20mA DC meter for observation. The maximum output load resistance is 300Ω. (0-20mA optional) |
| Signal communication | DB | Rs485 Communication input / output | RS485 communication input / output signal terminal, can be used for multiple soft starter connection. |
The List of Rated Power for SJR3-2000 Series
| Soft starter 230V/400V/660V 50/60Hz | Rated Power of the Motor |
| Soft Starter Model | Maximum current allowance (A) for class 10 | 220V | 380V | 660V |
| SJR3-2018 | 38 | 9kW | 18.5kW | 30kW |
| SJR3-2022 | 44 | 11kW | 22kW | 37kW |
| SJR3-2030 | 60 | 15kW | 30kW | 45kW |
| SJR3-2037 | 74 | 18.5kW | 37kW | 55kW |
| SJR3-2045 | 100 | 22kW | 45kW | 75kW |
| SJR3-2055 | 110 | 30kW | 55kW | 90kW |
| SJR3-2075 | 150 | 37kW | 75kW | 115kW |
| SJR3-2090 | 160 | 45kW | 90kW | 132kW |
| SJR3-2115 | 200 | 55kW | 115kW | 160kW |
| SJR3-2132 | 250 | 75kW | 132kW | 200kW |
| SJR3-2160 | 300 | 90kW | 160kW | 250kW |
| SJR3-2200 | 360 | 115kW | 200kW | 355kW |
| SJR3-2250 | 480 | 132kW | 250kW | 400kW |
| SJR3-2315 | 590 | 160kW | 315kW | 560kW |
| SJR3-2400 | 790 | 200kW | 400kW | -- |
| SJR3-2500 | 1000 | 250kW | 500kW | -- |
| SJR3-2630 | 1200 | 355kW | 630kW | -- |
Dimension
| Model | Dimension(mm) | G.W (kg) | Packing Dimension(mm) | 4 sets/carton | G.W (kg) |
| SJR3-2018 | 310*155**175 | 5 | 380*235*275 | 495**575*390 | 22 |
| SJR3-2022 |
| SJR3-2030 |
| SJR3-2037 |
| SJR3-2045 |
| SJR3-2055 |
| SJR3-2075 |
| SJR3-2090 | 400*270*240 | 20.5 | 650*390*380 | / | / |
| SJR3-2115 |
| SJR3-2132 |
| SJR3-2160 |
| SJR3-2200 |
| SJR3-2250 | 455*300*265 | 31 | 575*430*390 | / | / |
| SJR3-2315 |
| SJR3-2400 |
| SJR3-2500 |
| SJR3-2630 |
Address:
22 Liujiang Avenue, Liushi Town, Yueqing City, Zhejiang Province, Wenzhou, Zhejiang, China
Business Type:
Manufacturer/Factory
Business Range:
Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components
Management System Certification:
ISO 9001
Company Introduction:
Zhejiang Safesave Electrical Technology Co., Ltd focuses on industrial automation devices, electrical automation accessories and electrical complete units. Our products have been applied to some national key projects such as Shanghai World Expo, Beijing Olympic stadiums, South-to-North Water Division Project, Pudong international airport. Meanwhile, the factory was titled as a high-technology enterprise, science and technology enterprise, software enterprise, advanced enterprise in quality management, etc. Our company has research and development human resources from outstanding university research units such as Mechanical and Electrical Engineering and Automation Academy of Shanghai University, Information and Technology Academy of Fudan University. After the reorganization, the factory will do further research and manufacturing in high-end industrial automation equipment on the basis of previous achievement in the field of soft starter and variable frequency drive.