Home
Product Directory
Instruments & Meters
Meter for Electricity
Other Meters for Electricity
Power Supply Test System
| Negotiable | 1 Piece (MOQ) |
Min. Order:
1 Piece
Port:
Shenzhen, China
Production Capacity:
50
Payment Terms:
T/T
Shenzhen PTI Technology Co.,Ltd
Guangdong, China
Find Similar Products
Product Description
Company Info
Product Description
1,Summarize:
ATE9200 automatic test system, Adapt for AC/DC Input, The DC Output is a comprehensive test of Switch Power Supply. The system adopts a flexible hardware structure can be added based on customer's product testing requirements, convenience control equipment Costs.
System can compatible with different instruments, : (electronic load, oscilloscope, Power Analyzer, etc ). OS can develop different language
Adapt for Win98/Win200/XP/Win7.
Customer site can editing Test Step freely.
ATE-9200 automatic test system for customer requirements, combined with experience of industry specialist feedback re-design project, updated system structure/inside wiring and test fixture.
It made more convenient to do PM, operate easily, low operator time.
2,Instrument technical index
Variable frequency power supply
Electronic load
Power Meter
3. System test project
(Output characteristic)
(DC output voltage)
(DC output current)
(Peak-Peak noise)
(Efficiency)
(In-test adjustment)
(post test)
(D+D- Voltage test)
(QC2.0 test)
(QC3.0 test)
(Input characteristic)
(Input power, No load/Full)
(Input power factor)
(Input current)
(Input short circuit test)
(Capacitor discharge)
Stability Characteristic
(Current regulation)
(Voltage regulation)
(The comprehensive stability degree)
Protection Test
(Short test)
(The OCP over-current protection test)
(OL protection)
(OP protection)
(Comprehensive test)
(The average energy efficiency test)
(The on-line voltage adjustment)
(The on-line electric current adjustment)
(The voltage and current range automatic / manual selection)
(Analysis of the test data and save)
ATE9200 automatic test system, Adapt for AC/DC Input, The DC Output is a comprehensive test of Switch Power Supply. The system adopts a flexible hardware structure can be added based on customer's product testing requirements, convenience control equipment Costs.
System can compatible with different instruments, : (electronic load, oscilloscope, Power Analyzer, etc ). OS can develop different language
Adapt for Win98/Win200/XP/Win7.
Customer site can editing Test Step freely.
ATE-9200 automatic test system for customer requirements, combined with experience of industry specialist feedback re-design project, updated system structure/inside wiring and test fixture.
It made more convenient to do PM, operate easily, low operator time.
| Item | Name | Model/Spec | QTY | (Remarks) |
| 1 | Programmable frequency conversion power supply | ATA1000 | 1pcs | 1000VA |
| 2 | Programmable DC electronic load | LD1104 | 1pcs | 150V/30A/200W |
| 3 | Industrial control computer + display | IPC800A | 1pcs | (1.8G dual core 2G, RAM CPU + 64G solid state drive) |
| 6 | Windows Software | SN-880 | 1set | Decryption card |
| 7 | Standard Frame | 1set | Height of 160 cm | |
| 8 | External extended measurement unit | SN-640 | 1set | |
| 12 | Power meter | MT1204 | 1set | 300V/2A |
| 14 | training course | Class of 1 | free of charge |
2,Instrument technical index
Variable frequency power supply
| Model number | ATA1000 | |
| Capacitance | 500VA | |
| Making Method | linear amplification | |
| Input parameter | ||
| Phase number | 1Φ2W | |
| Voltage | 220V±10% | |
| Frequency | 47-63Hz | |
| output parameter | ||
| Phase number | 1Φ2W | |
| Voltage range | 0-150VAC/0-300VAC AUTO | |
| Frequency range | 47-63Hz,0.1Step | |
| Maximum current | 120V | 4.2A |
| 240V | 2.1A | |
| Electronic load regulation | 0.3% | |
| T.H.D Waveform distortion T.H.D | 0.3% | |
| Frequency stability | 0.01% | |
| Voltage resolution | 0.1V | |
| Frequency Resolution | 0.1Hz | |
| Current resolution | 0.001A | |
| Memory quantity | 3 | |
| COM Port | RS232C | |
| I-LIM Set O-Max Current | 0-4.2A | |
| Safeguard procedures | Over current, over temperature, over load, short circuit | |
| Weight | 30Kg | |
| Volume | 430mm*178mm*540mm | |
| Operating environment | 0-40ºC 20-80%RH | |
Electronic load
| Model number | JT6310A | ||
| Forehead set transport enter | Power | 120W | |
| Voltage | 0-15V | 0-150V | |
| Electric current | 0-3A | 0-20A | |
| Minimum operating voltage | 1V@20A | ||
| Minimum operating voltage | 10uS | ||
| CC mode | Range | 0-3A | 0-20A |
| Resolution ratio | 0.05mA | 0.5mA | |
| Accuracy | 0.03%+0.02%FS | ||
| CV mode | Range | 0-15V | 0-150V |
| Resolution ratio | 0.2mV | 2mV | |
| Accuracy | 0.03%+0.02%FS | ||
| CP mode | Range | 120W | |
| Resolution ratio | 16Bits | ||
| Accuracy | 0.1%+0.1%FS | ||
| CR mode | Range | 0.05Ω-50KΩ | |
| Resolution ratio | 16Bits | ||
| Accuracy | 0.1%+0.0001R | ||
| Dynamic operation mode | Range | 10uS-50S | |
| resolution ratio | 2uS | ||
| Accuracy | 1uS + 20PPM | ||
| Slew rate | 0.06A/Ms - 3 A/Ms | ||
| Voltage measurement | Range | 0-15V | 0-150V |
| Resolution ratio | 0.1mV | 1mV | |
| Accuracy | 0.015%+0.03%FS | ||
| Current measurement | Range | 0-3A | 0-20A |
| resolution ratio | 0.01mA | 0.1mA | |
| accuracy | 0.015%+0.08%FS | ||
| Ripple measurement | Range | 0-15V | 0-150V |
| bandwidth | 10Hz - 250KHz | ||
| accuracy | 0.03%+1mV | 0.03%+10mV | |
Power Meter
| parameter | parameter | operating error | resolving power | remarks |
| Voltage | (5~300)V | ±(0.4%Numerical reading+0.1%Measure Range) | 0.1V | Overload 1.2 times range |
| electric current | 0.5mA~20 mA /2A | ±(0.4%Numerical Reading+0.1%Measure Range), | 0.01mA | Overload 1.2 times range |
| power | U*I*PF | PF>0.5 ±(0.4%Numerical Reading+0.1%Measure Range ) PF<=0.5 ±(0.6%Numerical Reading+0.1%Measure Range) | 0.01W | |
| power factor | 0.1~1 | ± 0.01 | 0.001 | Voltage value is higher than 10% range; The current value is higher than the 1% range |
| frequency | (45~65)Hz | 0.1%*Numerical Reading | 0.01Hz | Voltage value is higher than 10% range |
3. System test project
(Output characteristic)
(DC output voltage)
(DC output current)
(Peak-Peak noise)
(Efficiency)
(In-test adjustment)
(post test)
(D+D- Voltage test)
(QC2.0 test)
(QC3.0 test)
(Input characteristic)
(Input power, No load/Full)
(Input power factor)
(Input current)
(Input short circuit test)
(Capacitor discharge)
Stability Characteristic
(Current regulation)
(Voltage regulation)
(The comprehensive stability degree)
Protection Test
(Short test)
(The OCP over-current protection test)
(OL protection)
(OP protection)
(Comprehensive test)
(The average energy efficiency test)
(The on-line voltage adjustment)
(The on-line electric current adjustment)
(The voltage and current range automatic / manual selection)
(Analysis of the test data and save)
Address:
4f No. 31, Songgang Road, Songgan Town, Shenzhen, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Instruments & Meters
Management System Certification:
ISO 9001
Main Products:
Pti-816s, in-Circuit-Test
Company Introduction:
Profressional In-circuit-test of the Shenzhen PTI.
Our products have below:
ICT (in-circuit-test)
PTI-816S
PTI-816
FCT(function test of the non-standard ) we can development base on Customer ideal.
Our products have below:
ICT (in-circuit-test)
PTI-816S
PTI-816
FCT(function test of the non-standard ) we can development base on Customer ideal.
Send your message to this supplier
People who liked this also liked