| Specification |
After-sales Service: 1 Year;
Warranty: 1 Year;
Appliance: Biochemistry;
Detector: Dad;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Infusion Pump: Dual Pump System;
Velocity Range: 0.01-300ml/Min;
Flow Accuracy: ±2%;
Back Pressure Valve Module: 20-200psi Adjustable, Biocompatible;
in-Line Filter Module: 20um Titanium Alloy Filter;
Dynamic Mixer Module: 2ml Mixing Chamber;
|
After-sales Service: Online Support;
Warranty: 1 Year;
Appliance: Food Analysis;
Gaspath System: Single;
Detector: FID;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Product Name: Gas Chromatograph;
Temp. Range: Rt+5~450℃;
Temp. Accuracy: ≤±0.1℃;
Temp. Program: 20-Phase;
Max. Temp. Heating Rate: 40℃/Min;
Internal Size: 250*270*170mm;
Injection Method: Various Injection Methods;
Hydrogen Flame Ionization Detector (Fid): Detection Limit:≤5×10-12g/S;
Thermal Conductivity Detector (Tcd): Sensitivity: >5000mv.Ml/Mg;
Flame Photometric Detector (Fpd): Detection Limit:≤5×10-12g/S;
Power Supply: AC220V±10%, 50/60Hz;
Standard Accessory: Fid Detector, Chromatography Workstation Software,;
Optional Accessory: Sample Injection System, Tcd, Fpd Detector,;
External Size(L*W*H): 530*502*508mm;
Package Size (W*D*H): 750*710*720mm;
|
After-sales Service: Online Service;
Warranty: 1year;
Appliance: The Analysis of Environmental Samples;
Ray Type: /;
Gaspath System: /;
Detector: /;
Energy Resolution: /;
Spectrometer Detector: UV;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 1~2mm;
Temperature Range: Ambient Temperature +7℃ ~ 400℃;
Temperature Accuracy: ± 0.02℃;
Cooling Time: 400℃ to 50℃ in 8-10 Min;
Programmed Temperature Setting: 0.1℃~40℃/Min (in 1℃ Increment);
Detection Limit: ≤3×10-12g/S (C16);
Best Test Result: ≤3×10-12g/S (C16);
Drift: ≤6×10-13A/30min;
Noise: ≤5×10-14A;
Linearity Range: ≥106;
Sensitivity: ≥5000mv, Ml/Mg (C16);
Baseline Noise: ≤20µV;
Detector Drift: ≤60µV/H;
Detector Linearity Range: ≥104;
|
After-sales Service: Online Service;
Warranty: 1year;
Appliance: The Analysis of Environmental Samples;
Ray Type: /;
Gaspath System: /;
Detector: /;
Energy Resolution: /;
Spectrometer Detector: UV;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 1~2mm;
Temperature Range: Ambient Temperature +7℃ ~ 400℃;
Temperature Accuracy: ± 0.02℃;
Cooling Time: 400℃ to 50℃ in 8-10 Min;
Programmed Temperature Setting: 0.1℃~40℃/Min (in 1℃ Increment);
Detection Limit: ≤3×10-12g/S (C16);
Best Test Result: ≤3×10-12g/S (C16);
Drift: ≤6×10-13A/30min;
Noise: ≤5×10-14A;
Linearity Range: ≥106;
Sensitivity: ≥5000mv, Ml/Mg (C16);
Baseline Noise: ≤20µV;
Detector Drift: ≤60µV/H;
Detector Linearity Range: ≥104;
|
After-sales Service: Response on Customers' Questions Within 12 Hours.;
Warranty: 12 Months;
Appliance: Transformer Oil;
Ray Type: Gas Chromatograph;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 0.2~0.5mm;
Gas Detection: H2, CH4, C2h4, C2h6, C2h2, Co, CO2, H2O;
Referemce Standard: IEC61850;
Description: Oil Dissolved Gas Analyzer Gas Chromatograph;
Communication Serial Port: 2 RS48;
Environment Temperature: -40 ~+55 Degree;
Relative Humidity: 5%~95%;
Atmospheric Pressure: 80kpa~110kp;
Altitude: 0~3000m;
Dimension: 1400*720*420mm;
Gross Weight: 292kg;
Language: English;
OEM Service: Available;
|