| Specification |
After-sales Service: 12month Warranty,Lifelong Technical Service;
Function: Inertial Sensors Testing;
Display: Digital;
Usage: Electric Component Tester, Inertial Sensors Testing;
Type: Motion Simulator;
Environment: Room Temperature;
Warranty: With Warranty;
Power Source: 220V;
Weight: 〉10Kg;
Installation: Direct Connected;
Customized: Customized;
Load Weight: 30kg;
Load Mounting Surface: ≥ φ300mm;
Countertop Flatness: ≤ ±5 Arcseconds;
Face Runout: ≤ 0.03mm;
Rate Range: 1°/S~300°/S;
Slip: 32 Rings;
|
Display: LCD;
Type: Transformer Tester;
Environment: High Temperature;
Warranty: With Warranty;
Power Source: DC 100V-300V;
Weight: 28kg;
Installation: Portable Precise;
Customized: Customized;
Output Voltage: 0.5~12kv;
Cx Accuracy: +-(Read*1%+1PF);
Tg&Delta Accurancy: +-(Read*1%+0.00040);
Internal Hv: 3PF~50000PF/12kv 60PF-1UF/0.5kv;
External Hv: 3PF~1.5UF/12kv 60PF~30UF/0.5kv;
Resolution: Max. 0.001PF, 4 Significant Figures;
CVT Self Excitation LV Output: Output Voltage 3~50V, Output Current 3~30A;
Test Current Range: 10ua~5A;
Setting Voltage Range: 0.5~12kv;
Keywords: C&Df Tester;
Test Frequency: 45, 50, 55, 60, 65Hz Single Frequency;
Test Frequency,Hz: 45/55Hz, 55/65Hz, 47.5/52.5Hz Auto Double Frequenc;
Frequency Precision: +-0.01Hz;
Communiation Port: RS232;
Printer: Build-in Thermal Printer;
|
Display: LCD;
Type: Transformer Tester;
Environment: High Temperature;
Warranty: With Warranty;
Power Source: DC 100V-300V;
Weight: 28kg;
Installation: Portable Precise;
Customized: Customized;
Output Voltage: 0.5~12kv;
Cx Accuracy: +-(Read*1%+1PF);
Tg&Delta Accurancy: +-(Read*1%+0.00040);
Internal Hv: 3PF~50000PF/12kv 60PF-1UF/0.5kv;
External Hv: 3PF~1.5UF/12kv 60PF~30UF/0.5kv;
Resolution: Max. 0.001PF, 4 Significant Figures;
CVT Self Excitation LV Output: Output Voltage 3~50V, Output Current 3~30A;
Test Current Range: 10ua~5A;
Setting Voltage Range: 0.5~12kv;
Keywords: C&Df Tester;
Test Frequency: 45, 50, 55, 60, 65Hz Single Frequency;
Test Frequency,Hz: 45/55Hz, 55/65Hz, 47.5/52.5Hz Auto Double Frequenc;
Frequency Precision: +-0.01Hz;
Communiation Port: RS232;
Printer: Build-in Thermal Printer;
|
Display: LCD;
Type: Transformer Tester;
Environment: High Temperature;
Warranty: With Warranty;
Power Source: DC 100V-300V;
Weight: 28kg;
Installation: Portable Precise;
Customized: Customized;
Output Voltage: 0.5~12kv;
Cx Accuracy: +-(Read*1%+1PF);
Tg&Delta Accurancy: +-(Read*1%+0.00040);
Internal Hv: 3PF~50000PF/12kv 60PF-1UF/0.5kv;
External Hv: 3PF~1.5UF/12kv 60PF~30UF/0.5kv;
Resolution: Max. 0.001PF, 4 Significant Figures;
CVT Self Excitation LV Output: Output Voltage 3~50V, Output Current 3~30A;
Test Current Range: 10ua~5A;
Setting Voltage Range: 0.5~12kv;
Keywords: C&Df Tester;
Test Frequency: 45, 50, 55, 60, 65Hz Single Frequency;
Test Frequency,Hz: 45/55Hz, 55/65Hz, 47.5/52.5Hz Auto Double Frequenc;
Frequency Precision: +-0.01Hz;
Communiation Port: RS232;
Printer: Build-in Thermal Printer;
|
Display: LCD;
Type: Transformer Tester;
Environment: High Temperature;
Warranty: With Warranty;
Power Source: DC 100V-300V;
Weight: 28kg;
Installation: Portable Precise;
Customized: Customized;
Output Voltage: 0.5~12kv;
Cx Accuracy: +-(Read*1%+1PF);
Tg&Delta Accurancy: +-(Read*1%+0.00040);
Internal Hv: 3PF~50000PF/12kv 60PF-1UF/0.5kv;
External Hv: 3PF~1.5UF/12kv 60PF~30UF/0.5kv;
Resolution: Max. 0.001PF, 4 Significant Figures;
CVT Self Excitation LV Output: Output Voltage 3~50V, Output Current 3~30A;
Test Current Range: 10ua~5A;
Setting Voltage Range: 0.5~12kv;
Keywords: C&Df Tester;
Test Frequency: 45, 50, 55, 60, 65Hz Single Frequency;
Test Frequency,Hz: 45/55Hz, 55/65Hz, 47.5/52.5Hz Auto Double Frequenc;
Frequency Precision: +-0.01Hz;
Communiation Port: RS232;
Printer: Build-in Thermal Printer;
|